Example Responses To Commands; Svs 100 Error Responses - Extron electronics SVS 100 User Manual

Seamless video switcher
Hide thumbs Also See for SVS 100:
Table of Contents

Advertisement

Serial Communication, cont'd
COMMAND
ASCII
Request Information
General
I
General
i

Example responses to commands

SVS 100 error responses

5-6
SVS 100 Communication
RESPONSE
T
•V
Exe
•Asw
•TpO
1. Response to Request general information (I) command:
T2222•V1•A2•Dur9•Eff02*01
Video type detected (T) = 2222 (PAL on all four inputs)
Video input selected (V) = 1 (video input 1)
Audio input selected (A) = 2 (audio input 2)
Duration of transition (Dur) = 9 (4.5 seconds)
Effect and transition (Eff) = 02 (soft wipe); 01 (right-to-left)
2. Response to Request general information (i) command:
Exe0•Asw1•TpO1•TpA1•TpB2
Executive mode (Exe) = 0 (off)
Audio switch mode (Asw) = 1 (audio switches channels halfway
Video output type (TpO) = 2 (PAL)
Video input 1 type (TpA) = 1 (auto)
Video input 2 type (TpB) = 2 (composite)
When the SVS 100 receives an SIS command and determines that it is valid,
it performs the command and sends a response to the host device. If the SVS
100 is unable to perform the command because the command is invalid or
contains invalid parameters, the SVS 100 returns an error response to the
host. The error response codes are:
E01
— Invalid input number
E09
— Invalid function number (too large)
E10
— Invalid command
E11
— Invalid preset
E13
— Invalid value (out of range)
DESCRIPTION
•A
•Dur
•Eff
*
Xk
Xe
Xt
TpA
•TpB
through the effect)