SEDIMENT CUP CLEANING

1. Move the fuel valve to the OFF position, and then remove the fuel
sediment cup, O-ring, and filter.
2. Wash the sediment cup and filter in non-flammable solvent, and dry it
thoroughly.
3. Place the filter and O-ring in the fuel valve, and install the sediment cup.
Tighten the sediment cup securely.
4. Move the fuel valve to the ON position, and check for leaks.
Replace the O-ring if there is any leakage.
Gasoline is highly flammable and
explosive.
You can be burned or seriously
injured when handling fuel.
• Stop the engine and keep heat,
sparks, and flame away.
• Handle fuel only outdoors.
• Wipe up spills immediately.
SERVICING YOUR TILLER
FUEL VALVE
OFF
Align
FILTER
O-RING
SEDIMENT CUP