Physical/Electrical Specifications; Ac Power Requirements; Dc Power Requirements - Seagate ST39173N Product Manual

Barracuda 9lp family
Table of Contents

Advertisement

Barracuda 9LP Product Manual, Rev. C
6.0

Physical/electrical specifications

This section provides information relating to the physical and electrical characteristics of the Barracuda 9LP
drive.
6.1

AC power requirements

None.
6.2

DC power requirements

The voltage and current requirements for a single drive are shown in the following table. Values indicated apply
at the drive power connector. The single ended power requirements includes the internal disc drive SCSI I/O
termination. The table shows current values in Amperes.
Table 2:
DC power requirements
Notes
Voltage
Regulation
[5][2] ±5% ±5%
Maximum operating
current DC
[1]
Average idle current
DCX
[1]
Maximum starting
current
(peak DC)
[3]
(peak AC)
[3]
Delayed motor start
(max) DC
[1][4] .65
Peak operating
current
Typical DCX
[1][6]
Maximum DC
[1]
Maximum (Peak)
[1]
Measured with average reading DC ammeter. Instantaneous +12 V current peaks will exceed these val-
ues.
[2]
For +12 V, a –10% droop is permissible during initial start of spindle, and must return to ±5% before 7,200
rpm is reached. The ±5% must be maintained after the drive signifies that its power-up sequence has
been completed and that the drive is able to accept selection by the host initiator.
[3]
See +12 V current profile in Figure 3a.
[4]
This condition occurs when the Motor Start Option is enabled and the drive has not yet received a Start
Motor command.
[5]
See Section 6.2.1 "Conducted Noise Immunity." Specified voltage tolerance is inclusive of ripple, noise,
and transient response.
[6]
Operating condition is defined as random seek read operations with a block count of 64.
General Notes from Table 2:
1. Minimum current loading for each supply voltage is not less than 4% of the maximum operating current
shown.
2. The +5 and +12 volt supplies shall employ separate ground returns.
3. Where power is provided to multiple drives from a common supply, careful consideration for individual drive
power requirements should be noted. Where multiple units are powered on simultaneously, the peak start-
ing current must be available to each device.
ST39173
N/W/WC
Single-
WD
ended
Differential
+5 V +12 V +5 V +12 V +5 V +12 V +5 V +12 V +5 V +12 V +5 V +12 V
±5% ±5%
1.15 .95
1.23 .95
.75
.5
.78
.5
1.2
1.7
1.23 1.7
2.9
2.9
.06
.67
.06
1.05
.9
1.16
.9
1.15
.95
1.23
.95
1.7
2.4
2.00
2.4
ST34573
N/W/WC
LC/LW
Single-
LVD
ended
±5% ±5%
±5% ±5%
1.4
.95
1.15 .95
.75
.5
.75
.5
1.2
1.7
1.2
1.7
2.9
2.9
.65
.06
.65
.06
1.2
.9
1.05
.9
1.4
.95
1.15
.95
1.7
2.4
1.7
2.4
WD
LC/LW
Differential
LVD
±5% ±5%
±5% ±5%
1.23 .95
1.4
.95
.78
.5
.75
.5
1.23 1.7
1.2
1.7
2.9
2.9
.67
.06
.65
.06
1.16
.9
1.2
.9
1.23
.95
1.4
.95
2.00
2.4
1.7
2.4
19

Hide quick links: