Anamorphic Lens Adjustment - Runco D-73d Ultra Installation & Operation Manual

3dimension series led home theater projection system
Table of Contents

Advertisement

If you are installing a D-73d with anamorphic lenses, proceed as follows to adjust them.
1. Select the Cinema aspect ratio using either the Dimension Digital Controller
remote control unit (see Figure 2-6) or the OSD menu (press MENU, then select
Aspect Ratio -> Cinema). (With a D-73d/CineWide with AutoScope, this should
position the anamorphic lens transport in front of the primary lenses.)
2. On the Dimension Digital Controller remote control or front panel, press MENU.
3. Select Calibration from the Main Menu.
4. Select Adjustment Mode from the Calibration Menu and set it to Primary.
5. Press EXIT (or MENU) repeatedly to return to the Main Menu.
6. Select Service from the Main Menu.
7. Select Test Video from the Service Menu and choose Primary Alignment.
Adjusting the Left (Top) Anamorphic Lens: Align the primary (left-eye) image with
the screen by adjusting the Left (top) anamorphic lens to produce the least amount of
distortion.
• Horizontal Position (X-adjust): Loosen the Yaw/X-Adjustment Levers underneath
the lens holder. Then, slowly move the anamorphic lens into place so that there are
no shadows on either side of the screen:
Too Far Left
Too Far Right
When the horizontal position is properly set, tighten the Yaw/X-Adjustment Levers to
secure the lens in place.
D-73d Series Installation/Operation Manual
Correct position
59