PARAMETERS
DESCRIPTION
PAR.
Defrost
Defrosting cycle activation.
d01
d03
Start defrosting pressure.
End defrosting pressure.
d04
Min. time to start a defrosting cycle.
d05
Min. duration of a defrosting cycle.
d06
d07
Max. duration of a defrosting cycle.
d08
Delay between 2 defrosting cycle requests with in the same circuit.
Defrosting delay between the 2 circuits.
d09
Fan
Fan operating mode:
0= Always ON.
F02
1=
Depending on compressor (in parallel operating mode).
2= Depending on compressors in ON/OFF control.
3= Depending on compressors in speed control mode.
Temp. value for min. speed cooling.
F05
Pressure value for min. speed cooling.
Differential value for max. speed in cooling mode (temp).
F06
Differential value for max. speed in cooling mode (pres).
Fan shut-down differential in cooling mode (temp).
F07
Fan shut-down differential in cooling mode (pres).
Temperature value for min. speed in heating mode.
F08
Pressure value for min speed cooling.
Differential value for max. speed in heating mode (temp).
F09
Differential value for max. speed in heating mode (pres).
Fan shut-down differential in heating mode (temp).
F10
Fan shut-down differential in heating mode (pres).
F11
Fan starting time.
Activation Low Noise:
0= Deactivate.
F15
1= Activate only in cooling mode.
2= Activate only in heating mode.
3= Activate both in cooling and heating mode.
F16
Differential Low Noise in cooling mode.
F17
Differential Low Noise in heating mode.
Setting
Activate remote change over:
H06
0= Deactivate.
1= Activate.
ON/OFF remoto:
H07
0= Deactivate.
1= Activate.
H10
Serial address.
H23
Activate Modbus.
H97
Expansion board software version.
H99
Software version.
Alarms
Enable part load in high pressure:
0= Capacity control deactivated.
P04
1= Capacity control activated for high pressure.
2= Capacity control activated for low pressure.
3= Capacity control activated for high and low pres.
CLIMATIC 40 User manual • MUL37E-0607 / 10-2008
MIN. MAX. VAR. UD.
0
1
1
fl ag
1
D04
0.1
bar
D03
/12
0.1
bar
10
150
1
sec.
0
150
1
sec.
1
150
1
min.
10
150
1
min.
0
150
1
min.
1 (EAC 1003-1804) 1 (ANCM 112D-152D) 1 (KSCM 112D-214D)
0
3
1
int.
2 (EAR 1003-1804) 2 (ANHM 112D-152D) 2 (KSHM 112D-214D)
3 (EAC/EAR 251-812)
-40
176
0.1
ºC
/11
/12
0.1
bar
20 (if F2=3) / 22 (if F2=2) 20 (if F2=3) / 22 (if F2=2) 20 (if F2=3) / 22 (if F2=2)
0
50
0.1
ºC
0
30
0.1
bar
0
50
0.1
ºC
0
F5
0.1
bar
-40
176
0.1
ºC
/11
/12
0.1
bar
0
50
0.1
ºC
0
30
0.1
bar
0
50
0.1
ºC
0
F8
0.1
bar
0
120
1
0
3
1
fl ag
0
50
0.1
bar
0
50
0.1
bar
0
1
1
fl ag
0
1
1
fl ag
1
200
1
ud.
0
1
1
fl ag
0
999
1
fl ag
0
999
1
fl ag
0
3
1
fl ag
BY DEFAULT
ECOLEAN
AIRCOOLAIR
1
1
5.7
5.7
35
30
60
60
0
0
8
8
40
40
10
10
3 (ANCM/HM 22E-86D) 3 (KSCM/HM 22E-86D)
28
28
12
12
6
6
10
10
2
2
30
30
12 (if F3=3) /
12 (if F3=3) /
22 (if F3=2)
22 (if F3=2)
1
1
5
5
0
0
13
13
20
20
0
0
5
5
1
1
0
0
1
1
1
1
0
0
1
1
AIRCUBE
1
5.7
30
60
0
8
40
10
28
12
6
10
2
30
12 (if F3=3) /
22 (if F3=2)
1
5
0
13
20
0
5
1
0 (KSCM) 1 (KSHM)
1
1
0
1