Install Indoor Unit - Gree GWC18KG-K3DNA5A Owner's Manual

Residential split type air conditioner
Hide thumbs Also See for GWC18KG-K3DNA5A:
Table of Contents

Advertisement

Install indoor unit

1. Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the
both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is
taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and
level should be 0 or more, that is good for condensing water drainage.
2. Fix the rear panel on the wall with screws. (Where is pre-covered with plastic granula)
3. Be sure that the rear panel has been fixed firmly enough to withstand the weight of an adult of 60kg,
further more, the weight should be evenly shared by each screw.
Wall
18K:
(Rear piping hole)
Wall
24K:
Left
Ф70
(Rear piping hole)
1. Make the piping hole (Ф55 Ф70) in the wall at a slight downward
slant to the outdoor side.
2. Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Install the rear panel
Mark on the middle of it
Space
to the
wall
m
1 5 0
m
above
Left
5
5
m
m
Ф
Mark on the middle of it
Space
to the
wall
1
5
0
mm
above
m
m
Install the piping hole
Gradienter
(Rear piping hole)
Gradienter
Fig.5
(Rear piping hole)
-20-
Wall
Space
to the
wall
1 50mm
above
Right
Ф
5
5
m
m
Wall
Space
to the
wall
1
5
0
m
m
above
Right
Ф70
m
m
Indoor
Wall pipe
Outdoor
Seal pad
Ф55
Ф70

Advertisement