Install indoor unit

1. Always mount the rear panel horizontally. As the water drainage pipe at the left, when
adjusting the rear panel, this side should not be too high; the right side should be slightly high.
2.Fix the rear panel on the selected
location.
3.Be sure that the rear panel has
been fixed
firm
enough to withstand
the weight of an adult of 60kg,
furthermore, the weight should be
evenly shared by each screw.
1. Make the piping hole (ф55) in the wall at a slight downward
slant to the outdoor side. At Fig.6.
2. Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
1.For well draining, the drain
placed at a downward slant.
2.
Do not wrench or bend the drain
its end by water.
3 .
When the long drainage
 
indoor, wrap
it with
1.Open the front panel upwardly;(Fig.6)
2. Screw off the fixing screw of cover plate
and screw off cover
3.
    Put the power connection cable through the
back of indoor unit wire hole and take it out.
4. Connect the wire according to figure 8,
connection should be done correspondingly
one by one according to the wire board mark .
5. Put the power connection cable the section,
that
with sheath into wire groove, and cover
the cover plate, screw on the fixing screw,
tighten the connection wire.
6.  Cover the front panel cover.
For the cooling and heating unit, signal control
7.
wire can be passed through the connection of
connector and indoor unit, and use the wire clip
that is under the body case, tighten the signal
control wire (As show in Fig. 9)
Install the rear panel
Wall
(Rear piping hole)
Install the piping hole
Install the water drainage pipe
pipe
should be
pipe
pipe
passing through
insulation materials.
Connect indoor and outdoor electric wires
plate (As show in Fig. 7)
Mark on the middle of it
Space to
the wall
150mm
above
Left
φ55mm
or flood
Power connection wire
19
Gradienter
Fig.6
Indoor
Wall pipe
Wrenched
Wire terminal
cover plate
Wire in unit
Power
connection
Connector
wire
Fig.7
Fig. 8
Wall
Space to
the wall
150mm
above
Right
φ55mm
(Rear piping hole)
Outdoor
Seal pad
55
Ø
Protection
sleeve pipe
Bent
Flooded
Signal control
wire
(4X0.75)
Fig. 9