Black Box ACU5051A User Manual

Black Box ACU5051A User Manual

Servswitch srx

Advertisement

®

NETWORK SERVICES

Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
CUSTOMER
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
SUPPORT
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
INFORMATION
Web site: www.blackbox.com • E-mail: info@blackbox.com
®
ServSwitch

USER GUIDE

SRX
FEBRUARY 2009
ACU5051A
ACU5052A
contents

Advertisement

Table of Contents
loading

Summary of Contents for Black Box ACU5051A

  • Page 1: Network Services

    Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) CUSTOMER FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 SUPPORT contents Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 INFORMATION Web site: www.blackbox.com • E-mail: info@blackbox.com...
  • Page 2: Table Of Contents

    Contents ® Welcome Operation Introduction..................2 General.use.................13 Supplied.items................3 Dual.user.arbitration..............13 Optional.items................4 Peripheral.operation..............13 Installation Further information Connections..................5 Getting.assistance...............14 Mounting..................5 Troubleshooting.................14 Connections.at.the.local.module..........6 Safety.information..............15 Local.module.power............7 Radio.Frequency.Energy............16 Connections.at.the.remote.module........8 Normas.Oficiales.Mexicanas.(NOM).statement......17 Dual.user.configuration............10 Instrucciones.de.seguridad..........17 Video.display.(DDC).information..........11 BlackBox.subsidiary.contact.details...........19 Video.sharpness.adjustment..........12...
  • Page 3: Introduction

    SRX extenders provide the power and flexibility to and two other USB channels are all readily and errors. reliably available at up to 50 metres away. create the right solution. BLACK BOX BLACK BOX POWER POWER CATx link cable(s) SHARPNESS...
  • Page 4: Supplied.items

    Supplied items ® Wizard SRX standard extender modules Rack mount USB (A to B plate for SRX type) lead standard module (useable for the local or remote modules) Video lead (5 way, male to male) SRX local SRX remote module module Self adhesive feet...
  • Page 5: Optional.items

    Optional items ® Power adapter and country- specific power lead for local module (if USB powering not possible) Rack mount chassis...
  • Page 6: Installation

    Installation ® Connections Mounting Installation of the SRX modules is straightforward with minimal configuration The SRX modules offer two main mounting methods: requirements in most cases. • Supplied four self-adhesive rubber feet • Connections.at.the.local.module • Rack mount brackets - see below •...
  • Page 7: Connections.at.the.local.module

    Connections at the local module ® 1 Where possible ensure that power is disconnected from the computer 3 Optionally connect local speakers system to be connected. to the audio output connector on the local module. 2 Attach the video, USB (see the Important note on page 5) and (optionally) audio connections from the computer system to...
  • Page 8: Local.module.power

    ‘LINK 2’ socket on the local need to purchase and use a power supply identical to the one used module. for the remote module from your Black Box stockist. 1 If external power input is necessary, attach the output Low power...
  • Page 9: Connections.at.the.remote.module

    Connections at the remote module ® 1 Place the remote module adjacent to the user location. 3 Attach the leads of up to four USB devices (two of which are 2 Attach the lead from the video usually a keyboard and mouse) monitor to the video out socket to the sockets located adjacent on the remote module.
  • Page 10 5 Optionally attach the lead from ® 7 Attach the output connector your stereo speakers to the audio of the power supply to the output socket on the remote ‘POWER’ socket of the remote module. module. To speakers 6 Attach the connector of the category 5, 5e or 6 link cable To power (up to 50 metres in length) to...
  • Page 11: Dual.user.configuration

    Arbitration between the two positions is handled by the computer’s USB system and so this arrangement is better suited to situations where two users would not often require simultaneous access. USER BLACK BOX POWER SHARPNESS REMOTE LINK TO LOCAL ®...
  • Page 12: Video.display.(Ddc).Information

    Video display (DDC) information ® DDC indications The Display Data Channel (or DDC) is an industry standard scheme which allows video monitors to declare their capabilities to the computer’s video adapter When power is first applied to the local module (either from circuitry, allowing the latter to optimise their outputs accordingly.
  • Page 13: Video.sharpness.adjustment

    Video sharpness adjustment ® The Wizard SRX remote module includes a straightforward video adjustment to control picture sharpness on the remote monitor. To adjust video sharpness 1 On the computer, display a suitable high contrast image (see right). To display a suitable high contrast image The best way to clearly view the effect of 2 Insert a small flat-bladed sharpness and brightness adjustments is to...
  • Page 14: Operation

    USB typically require 100mA. Each X50 contains a self-resetting fuse that will prevent sub-system of the computer. Unlike with other Black Box products, this means damage by shutting down the unit if the total power draw becomes excessive.
  • Page 15: Further Information

    Further information ® Troubleshooting Getting assistance If you are still experiencing problems after checking the list of solutions in the Status indicators Troubleshooting section then we provide a number of other solutions: The green and yellow indicators built into the link connectors on each module provide useful feedback regarding the connection and power status: •...
  • Page 16: Safety.information

    Safety information ® • For use in dry, oil free indoor environments only. • Do not use to link between buildings. • Ensure that all twisted pair interconnect cables are installed in compliance with all applicable wiring regulations. • Do not connect CATx link interfaces (RJ45 style connectors) to any other equipment, particularly network or telecommunications equipment.
  • Page 17: Radio.frequency.energy

    Radio Frequency Energy ® A Category 5 (or better) twisted pair cable must be used to connect the units in order to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances. All other interface cables used with this equipment must be shielded in order to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances.
  • Page 18: Normas.oficiales.mexicanas.(Nom).Statement

    Normas Oficiales Mexicanas (NOM) electrical ® safety statement Instrucciones de seguridad 15 En caso de existir, una antena externa deberá ser localizada lejos de las 1 Todas las instrucciones de seguridad y operación deberán ser leídas antes de lineas de energia. que el aparato eléctrico sea operado.
  • Page 19 ® © 2009 Black Box Corporation All trademarks are acknowledged. Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018, United States of America Tel: +1-724-746-5500 Fax: +1-724-746-0746 Documentation by: www.ctxd.com...
  • Page 20: Blackbox.subsidiary.contact.details

    BlackBox subsidiary contact details ® Country Web Site/Email Phone United States www.blackbox.com 724-746-5500 724-746-0746 Austria www.black-box.at +43 1 256 98 56 +43 1 256 98 56 support@black-box.at Belgium www.blackbox.be +32 2 725 85 50 +32 2 725 92 12 support.nederlands@blackbox.be support.french@blackbox.be support.english@blackbox.be Denmark...

This manual is also suitable for:

Acu5052a

Table of Contents