NOTICE: Termination cap should pass through the wall firestop
from the exterior of the building. Adjust the termination
cap to its final exterior position on the building.
Termination cap must be positioned so that arrow is pointing
up.
Attach the termination cap with the four wood screws provided.
Before attachment of the termination, run a bead of silicone sealant
rated above 250°F on its outside edge too, so as to make a seal
to the exterior wall.
NOTICE: Wood screws can and should be replaced with appropriate
fasteners for use on stucco, brick, concrete or other types
of siding.
If exterior walls are finished with vinyl siding, (or materials that
could become discolored or warp) it is necessary to install a vinyl
siding standoff.
The vinyl siding standoff will be installed between the vent termination
and the exterior wall. See Figure 47. This horizontal vent termination
bolts onto the flat portion of the vinyl siding standoff, so an air space
will exist between the wall and the termination cap.
Page 28
HORIZONTAL TERMINATION
WARNING
CAUTION
Figure 47
28651-2-0811