Installation - Empire Comfort Systems DVP42DP31N-2 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

HORIZONTAL ONLY, STRAIGHT OUT THE BACK
"
A"
PIPE LENGTH
"A"
6"(152mm)
5 1/8"(130mm) to 6 /2"(165mm)
9"(229mm)
8 1/8"(206mm) to 91/2"(241mm)
12"(305mm) 11 1/8"(283mm) to 12 1/2"(317mm)
VERTICAL, 90° ELBOW TO
HORIZONTAL OUT THE WALL
90º ELBOW
"B"
"A"
"B"
6"(152mm)
11 1/4"(286mm) to
12 3/4"(324mm)
9"(229mm)
14 1/4"(362mm) to
15 3/4"(400mm)
12"(305mm)
17 1/4"(438mm) to
18 3/4"(476mm)
CORNER INSTALLATION VERTICAL, 90° ELBOW TO
HORIZONTAL OUT THE WALL
28651-2-0811
INSTALLATION (continued)
VENT CAP
WALL FIRESTOP/
THIMBLE
"B"
Figure 18
"A"
PIPE
LENGTH
VENT CAP
WALL FIRESTOP/
THIMBLE
"C"
"C"
4 3/4"(121mm) to
6 1/4"(159mm)
7 3/4"(197mm) to
9 1/4"(235MM)
10 3/4"(273mm) to
12 1/4"(311mm)
Figure 19
MODEL
DVP 42
DVP 42
DVP 42
CORNER INSTALLATION HORIZONTAL, 45° ELBOW TO
WALL FIRESTOP/
THIMBLE
Dim.
DVP42
45 3/8"
A
1152mm
32 1/8"
B
816mm
13 3/8"
C
34 mm
64 1/8"
D
1628mm
Figure 20
HORIZONTAL OUT THE WALL
DVP42
"A"
"B"
6"(152mm)
4"(102mm) to
5 1/2"(140mm)
9"(229mm)
6"(152mm) to
7 /2"(191mm)
12"(305mm) 9"(229mm) to
10 1/2"(267mm)
Figure 21
WALL FIRESTOP/
THIMBLE
VENT
CAP
Page 15