ResMed VPAP Auto User Manual

Positive airway pressure device
Hide thumbs Also See for VPAP Auto:

Advertisement

VPAP
Auto
POSITIVE AIRWAY PRESSURE DEVICE
User Guide
English

Advertisement

Table of Contents
loading

Summary of Contents for ResMed VPAP Auto

  • Page 1 VPAP Auto ™ POSITIVE AIRWAY PRESSURE DEVICE User Guide English...
  • Page 2 © 2007 ResMed Ltd. © 2007 ResMed Ltd. © 2007 ResMed Ltd. © 2007 ResMed Ltd.
  • Page 3 © 2007 ResMed Ltd. © 2007 ResMed Ltd. © 2007 ResMed Ltd. © 2007 ResMed Ltd.
  • Page 4 VPAP Auto ™ OSITIVE IRWAY RESSURE EVICE User Guide English...
  • Page 5 1267271, NZ 405614, NZ 406923, NZ 406924. Others pending. HumidAire, HumidAire 3i, SmartStart, AutoSet, ResScan,Ti Control, Ultra Mirage, VPAP , Vista and VPAP Auto are trademarks of ResMed Ltd. HumidAire, SmartStart, Vista, AutoSet and VPAP are registered in U.S. Patent and Trademark Office.
  • Page 6: Table Of Contents

    Starting Treatment SmartStart™ Stopping Treatment Using the Mask-Fitting Feature Messages on the VPAP Auto LCD Modules Helpful Hints Cleaning and Maintenance ....... . 25...
  • Page 7 Contents...
  • Page 8: Introduction

    Introduction Definitions This guide contains special terms and icons that appear in the margins to draw your attention to specific and important information. Warning alerts you to possible injury. • Caution explains special measures for the safe and effective use of the •...
  • Page 10: Medical Information

    • recommended by ResMed, or by a physician or respiratory therapist. A mask should not be used unless the VPAP Auto device is turned on and operating properly. The vent hole or holes associated with the mask should never be blocked.
  • Page 11: Warnings Related To Treatment

    This applies to most models of PAP devices. In the event of power failure or machine malfunction, remove the mask. • The VPAP Auto can be set to deliver pressures up to 20 cm H O. In the •...
  • Page 12: Cautions

    C) higher than the temperature of the room. Caution should be exercised if the room temperature is warmer than 90 F (32 When AC mains power (100/240V AC) is not available, always use a ResMed • DC-12 converter. (The DC-12 converter is available as an optional accessory.) If supplied, the ResScan™...
  • Page 14: The Vpap Auto System

    In VAuto mode, only ResMed masks are compatible for use with the • VPAP Auto. Your clinician needs to set up your VPAP Auto for use with your particular • mask. Humidifier Please refer to the illustration in section B of the illustration sheet.
  • Page 15: Supplemental Oxygen

    • Note: ResMed recommends the following tubing products for use with the VPAP Auto: 9’ 9" (3 m) air tubing, gray (PN: 14980); 6’ 6" (2 m) air tubing, gray (PN: 14948); disposable air tubing, clear (PN: 14912). Supplemental Oxygen The VPAP Auto is designed to be compatible with the use of low flow oxygen therapy provided from an external source.
  • Page 16: Preparing For Use

    Be careful not to place the device where it can be bumped or where someone is likely to trip over the power cord. Note: You can also place your VPAP Auto on the floor beside or underneath your bed. Ensure that the area is free from dust and clear of bedding, clothes or any other objects that could block the air inlet.
  • Page 17 The VPAP Auto is not compatible with external humidifiers. HumidAire 3i humidifier The HumidAire 3i attaches to the front of the VPAP Auto to provide heated humidification. No other accessories are required for its use. The VPAP Auto automatically detects the presence of the HumidAire 3i. No menu changes are required.
  • Page 18 Features of the VPAP Auto The control panel of the VPAP Auto unit includes a keypad for navigating through the menus and delivering treatment. LCD screen Up key Left key Right key Down key Start/Stop Key Figure 1: VPAP Auto Keypad and LCD The LCD is used to display the menus and other data.
  • Page 19: Using The Menus

    VPAP Auto. The Used (time) screen displays the total number of hours for which you have used the device since it was last reset by the clinician. It also displays the number of days the VPAP Auto was used out of...
  • Page 20 Figure 2 summarizes the VPAP Auto standard menu series. To access the VPAP Auto menus: • Press the Left key (menu) while the VPAP Auto (or Ramp or Settling) screen is displayed. To scroll through items within the menu: •...
  • Page 21 Menus with a ResLink and Oximeter If your clinician has recommended that you use a ResLink module, and the ResLink and an oximeter are connected to the VPAP Auto, then display of SpO (oxygen saturation) and HR (heart rate) takes priority. If treatment has not...
  • Page 22: Operating Instructions

    Operating Instructions Starting Treatment The VPAP Auto unit should be assembled beside your bed with the air tubing and mask system connected. See “Setting Up the VPAP Auto” on page 9. Plug the power cord into the power source. A welcome message is displayed on the LCD screen.
  • Page 23 Note: Make sure that the mask setting on the MASK screen is the same as the mask you are using. To use the mask-fitting feature: Fit your mask as described in the mask user instructions. Hold down the Start/Stop key for at least three seconds until air pressure delivery starts.
  • Page 24 Treatment mode: Mode of treatment set by your clinician. Options are: CPAP, S and VAuto. Ramping indicator: (CPAP mode, S mode) Appears if the VPAP Auto is in ramp mode. This disappears once the ramp time has elapsed. Settling indicator: (VAuto mode) Appears if the VPAP Auto is in settling mode.
  • Page 25: Ramp Time

    If you have difficulty falling asleep with the VPAP Auto operating, select a settling time. The airflow will remain at Minimum Pressure for the period of time that you set, giving you time to fall asleep. After this time, the VPAP Auto will be able to increase pressure in response to events.
  • Page 26: Messages On The Vpap Auto Lcd

    Mirage Vista Nasal Mask Messages on the VPAP Auto LCD Your clinician may have set your VPAP Auto to remind you about important events, such as when to replace your mask, when to insert your Data Card (if your device is Data Card enabled) and so on.
  • Page 27: Modules

    The blank module is a protective cover on your VPAP Auto. At times, you may wish to remove or attach the module, for example to use another module. To remove the blank module, pull it off the back of the VPAP Auto to show the data communications port (F-1).
  • Page 28: Using The Data Card To Collect Data

    If your clinician needs to review your treatment, they will ask you to use the Data Card to copy data from your VPAP Auto, and to return the card to them. The Data Card will be provided in a convenient mailback envelope.
  • Page 29: Helpful Hints

    2. Place the mailback envelope containing the Data Card in a postal envelope and seal it. 3. Make sure that your clinician’s name and address details are on the postal envelope, and mail it back immediately. Using the Data Card to Update Settings If your clinician has provided a Data Card with new device settings: With the device in standby (RAMP or SETTLING) mode, insert the Data Card •...
  • Page 30 Consult your clinican for advice. Use with DC Power You must use a ResMed DC-12 converter to connect the VPAP Auto to a 12 V or 24 V DC power source. Contact your equipment supplier or ResMed for details.
  • Page 32: Cleaning And Maintenance

    4. Reconnect the air tubing to the air outlet and mask. Periodic Cleaning 1. Clean the exterior of the VPAP Auto with a damp cloth and mild liquid soap. 2. Check the air filter for blockage or holes (see “Replacing the Air Filter” on page 26).
  • Page 33: Replacing The Air Filter

    Inspect the air filter every month to check if it is blocked by dirt or contains holes. With normal use of an VPAP Auto, the air filter needs to be replaced every six months (or more often if your device is in a dusty environment).
  • Page 34: Troubleshooting

    Troubleshooting If there is a problem, try the following suggestions. If the problem cannot be solved, contact your equipment supplier or ResMed. Do not attempt to open the device. Problem Possible Cause Solution No display. Power not connected. Ensure the appropriate power...
  • Page 35 Air tubing not connected properly. Connect firmly at both ends. Air tubing kinked or punctured. Straighten or replace. VPAP Auto unit does SmartStop is disabled. Enable SmartStop if possible. not stop when you Note: SmartStop is not available remove your mask.
  • Page 36 Check tube!! front of the VPAP Auto. Key if done When you have checked the air tubing, press the Start/Stop key to restart the device. If this does not clear the...
  • Page 37 Problem Possible Cause Solution The card is not a ResScan Data Only use a ResScan Data Card. Card. The following The Data Card is not inserted Ensure that the Data Card is message is displayed correctly. inserted with the arrow facing on the LCD after you up and pointing toward the try to copy data to a...
  • Page 38: Technical Specifications

    Technical Specifications Performance Operating pressure range: 3 to 20 cm H Maximum single fault pressure: 30 cm H Pressure measurement tolerance: ±0.5 cm H O ± 4% of the measured reading Flow measurement tolerance: ±0.1 or 20% of reading, whichever is greater. Dynamic pressure characteristics VAuto mode: 4 to 20 cm H O (measured at the mask);...
  • Page 39: Accessories

    Noise Level VPAP Auto—CPAP mode, 10 cm H O set pressure Measured total A-weighted sound pressure level 24 dBA (dB re 20 μPa) Uncertainty (dB re 20 μPa) 2 dBA Measured values are determined according to the noise test procedure given in ISO 17510-1.
  • Page 40 Drip proof Dangerous voltage Start/Stop and Mask fit Technical Specifications...
  • Page 41 Guidance and manufacturer’s declaration—electromagnetic emissions The VPAP Auto device is intended for use in the electromagnetic environment specified below. The customer or the user of the VPAP Auto device should assure that the device is used in such an environment.
  • Page 42 Guidance and manufacturer’s declaration—electromagnetic immunity The VPAP Auto device is intended for use in the electromagnetic environment specified below. The customer or the user of the VPAP Auto device should assure that the device is used in such an environment.
  • Page 43 Guidance and manufacturer’s declaration—electromagnetic immunity The VPAP Auto device is intended for use in the electromagnetic environment specified below. The customer or the user of the VPAP Auto device should assure that the device is used in such an environment.
  • Page 44 VPAP Auto series of devices The VPAP Auto device is intended for use in an environment in which radiated RF disturbances are controlled. The customer or the user of the VPAP Auto device can help prevent electromagnetic...
  • Page 46: Limited Warranty

    ResMed shall not be responsible for any incidental or consequential damages claimed to have occurred as a result of the sale, installation or use of any ResMed product. Some regions or states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
  • Page 48: Index

    13 Modules attaching 7 Electromagnetic Compatibility 32 Mouth leaks 22 Error messages 29 Nasal irritation 23 Features of the VPAP Auto 11 Noise level 32 Headgear position 27 Operating instructions 15 Helpful hints 22 Oxygen HumidAire 3i 10...
  • Page 49 Technical specifications 31 Traveling 23 Troubleshooting 27 Up key 11 Use on aircraft 23 Used (time) screen 12 User/owner responsibility 1 Using the menus 12 VPAP Auto dimensions 32 servicing 26 Warnings related to treatment 4 Warranty 39 Weekly cleaning 25...
  • Page 50 268108/2 07 08 VPAP Auto User AMER Global leaders in sleep and respiratory medicine www.myresmed.com...