51I ACC Wood Insert
5

Service Parts Replacement

A. Glass Replacement - Door Assembly
(Replace with 5mm ceramic glass only)
1. Ensure that the fire is out and the appliance is cool to
the touch.
2.
Protect a table or counter top with padding or towels.
Protect your hands and wear gloves to prevent injury.
3.
Remove the door with the broken glass by lifting the door
up and off of the hinges.
4.
Lay door face down on a table or counter making sure
the handle hangs over the edge so the door lays flat, on
a soft surface.
5.
Remove the screws from each glass retainer and remove
the glass. (If screws are difficult to remove, soak with
penetrating oil first).
6.
Center the glass with edges evenly overlapping the
opening in the door, (i.e. same space top and bottom,
left and right sides).
7.
Replace the glass retainers. Be careful not to cross
thread the screws.
8. Tighten each retainer just a few turns until each is
secured. Check again for centering of glass in door
frame. Continue to tighten each retainer alternately, a
few turns at a time, until the glass is secure. DO NOT
OVERTIGHTEN - can cause glass to break.
9.
Replace the door on the appliance.
WARNING! Risk of Fire or Injury!
Use only glass that is specified in the manual, DO NOT
replace with any other material. Glass breakage will occur.
CAUTION!
Handle glass with care.
• Inspect the gasket to ensure it is undamaged.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass & door assembly
removed.
• Do NOT operate with glass cracked, broken or
scratched.
Quadra-Fire appliances are equipped with ceramic super
heat-resistant glass, which can only be broken by impact or
misuse.
CAUTION
Shock Risk.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
22
B. Blower Replacement
1.
Using a 5/32 Allen wrench remove the 4 screws from the
blower housing, 2 on each side. and pull the housing away
from the appliance.
2. Remove the blower shield assembly using a Phillips head
screwdriver and remove the 4 screws. Disconnect snap
disc from the wire harness. Figure 22.2.
3. Turn the blower assembly upside down and disconnect the
blower from the wire harness.
4. Remove the 4 blower mounting screws using a Phillips head
screwdriver. Slide blower off of blower mounting bracket.
Figure 22.3.
5. Install new blower and attach to housing and appliance in
reverse order.
Figure 22.1
Retirez les 4 vis
Figure 22.2
Blower Mounting Bracket
Remove 4 screws
Figure 22.3
7047-911
Figure 22.1.
Remove 4 screws and
pull housing away from
appliance
Assemblée
Bouclier ventilateur
October 7, 2013