J. Correct Baffle & Blanket Placement
WARNING
Fire Risk
Improper baffle placement may cause:
• Overheating of firebox
• Overheating the chimney
Baffle must be placed properly (see instructions)
Replace baffle if damaged or missing.
NOTE: A missing, damaged or improperly positioned baffle
is dangerous and may cause damage and poor efficiency.
It will also void your warranty.
Note: This are generic drawings and may
not represent your specific model.
CORRECT POSITION
Ceramic Blanket
Baffle Retainer Bracket
Baffle Board
Ceramic Blanket and Baffle Board MUST be in
contact with the back of the firebox and even
with each other in the front.
Figure 13.1 - Correct Baffle and Blanket Positions
October 7, 2013
Ceramic Blanket and Baffle Board are NOT
in contact with the back of the firebox.
Back of Firebox
Ceramic Blanket is bunched up at the back
of the firebox and NOT even with the Baffle
Board in the front.
Figure 13.2 - Incorrect Baffle and Blanket Positions
7047-911
INCORRECT POSITIONS
Ceramic Blanket is NOT in contact with the
back of the firebox and NOT even with the
Baffle Board in the front.