HP ProLiant DL360 Quickspecs page 56

Generation 7
Hide thumbs Also See for ProLiant DL360:
Table of Contents

Advertisement

QuickSpecs
Technical Specifications
Altitude
Altitude
Altitude
Altitude
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Emissions Classification
Emissions Classification
Emissions Classification
Emissions Classification
(EMC)
(EMC)
(EMC)
(EMC)
DA - 13598
North America — Version 40 — October 10, 2011
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
the product is operating in a 23° C ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared in
accordance with ISO 9296 (ECMA 109).
Idle (Single Processor, Note 1)
Idle (Single Processor, Note 1)
Idle (Single Processor, Note 1)
Idle (Single Processor, Note 1)
L WAd
L pAm
Operating
Operating
Operating
Operating
L WAd
L pAm
Idle (Dual Processors, Note 2)
Idle (Dual Processors, Note 2)
Idle (Dual Processors, Note 2)
Idle (Dual Processors, Note 2)
L WAd
L pAm
Operating
Operating
Operating
Operating
L WAd
L pAm
NOTES:
NOTES:
NOTES:
NOTES:
Note 1) Configuration tested included an Intel X5520 quad-core 2.27GHz
processor, one 72GB SAS HDD, four 250GB 5400 rpm SATA hard drives,
six system fans, three 4GB(2x2GB) DIMM's, and one power supply (1P SKU).
Note 2) Configuration tested included two Intel X5520 quad-core 2.27GHz
processors, one 72GB SAS HDD, four 250GB 5400 rpm SATA hard drives,
eight system fans, six 4GB(2x2GB) DIMM's, and one power supply (2P SKU).
Note 3) Values are subject to change without notification and are for
reference only.
Note 4) Performance of system, options, and ancillary equipment will vary
depending on the system configuration.
Note 5) Levels presented do not account for non-Hewlett-Packard installed
hardware.
FCC Rating
Normative Standards
HP ProLiant DL360 Generation 7 (G7)
HP ProLiant DL360 Generation 7 (G7)
HP ProLiant DL360 Generation 7 (G7)
HP ProLiant DL360 Generation 7 (G7)
5 to 95% relative humidity (Rh), 38.7° C (101.7°
F) maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
4.3 B Average Bystander
27 dBA
4.8 B Average Bystander
32 dBA
4.9 B Average Bystander
33 dBA
5.4 B Average Bystander
38 dBA
Class A
CISPR 22; EN55022; EN55024; FCC CFR 47,
Pt 15; ICES-003; CNS13438; GB9254; K22;
K24; EN 61000-3-2; EN 61000-3-3; EN
60950-1; IEC 60950-1
Page 56

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant dl360 generation 7Hp dl360 g7

Table of Contents