controller or to run synchronized on two or more fixtures set to a master/slave operating
mode. The combined number of channels required by all the fixtures on a serial data link
determines the number of fixtures the data link can support.
Maximum recommended serial data link distance:500 meters(1640ft).
Maximum recommended number of fixtures on a serial data link:32 fixtures.
Data cabling
To link fixtures together you must obtain data cables. If you choose to create your own
cable please use data-grade cables that can carry a high quality signal and are less
prone to electromagnetic interference.

3.3 3-Pin to 5-Pin conversion chart

Note! If you use a controller with a 5 pin DMX output connector. you will need to use a
5pin to 3 pin adapter.
The chart below details a proper cable conversion:

3.4 Setting up a DMX serial data link

at first link the first light and DMX control through XLR-connection signal cable, then
connect the light in series as the follow

3.5 Master/Slave fixture linking

1.Connect the (male) 3 pin connector side of the DMX cable to the output (female)3pin
connector of the first fixture.2.Connect the end of the cable coming from the first fixture
which will have a (female)3 pin connector to the input connector of the next fixture
consisting of a (male) 3 pin connector. Then, proceed to connect from the output as
stated above to the input of the following fixture and so on.

3.6 orientation

This fixture may be mounted in any position provided there is adequate room for
ventilation.