TIP
The economy control switch must be turned to "OFF"
when using electric devices that require a large start-
ing current, such as a compressor or a submersible
pump.
AE01099
DC PROTECTOR
The DC protector turns "OFF" automatically when
electric device being connected to the generator is
operating and current above the rated flows. To use
this equipment again, turn on the DC protector by
pressing its button to "RESET".
763-224a
1
Direct current is output. (This is the default position.)
2
2
1
Direct current is not output.
NOTICE
763-238a
Reduce the load of the connected electric device
below the specified rated output of the generator if
the DC protector turns off. If the DC protector
turns off again, stop using the device immediately
and consult a Yamaha dealer.
AE01021
FUEL TANK CAP AIR VENT KNOB
The fuel tank cap is provided with an air vent knob to
1
stop fuel flow.
2
The air vent knob must be turned 1 turn counterclock-
wise from the tightened position. This will allow fuel to
flow to the carburetor and the engine to run.
When the engine is not in use, tighten the air vent
knob clockwise until it is finger-tight to stop fuel flow.
1 Air vent knob
2 Fuel tank cap
707-096
I
"RESET"
3 "OFF"
– 8 –