Spec Sheet Cisco UCS C22 M3 High-Density Rack-Mount Server (Small Form Factor Hard Disk Drive Model) ISCO YSTEMS UBLICATION ISTORY 170 W ASMAN , CA, 95134 27, 2014 CISCO...
IT and web infrastructure, VPN servers, file/print servers, and appliances. Building on the success of the Cisco UCS C-Series Servers, the Cisco UCS C22 M3 server and the Cisco 1225 VIC further extend the capabilities of the Cisco UCS portfolio in a 1RU form factor with the addition of the Intel®...
Expansion slots Two riser cards with one PCIe card slot in each riser Riser 1 (controlled by CPU 1) ■ • Slot 1: PCIe Gen 3 slot, x16 extended connector (Cisco CNIC), half-length, full-height, with NCSI and Cisco CNIC support. The Cisco 1225 virtual interface card requires an NCSI slot.
Page 7
650 W power supply. The UCS Power Calculator can be found at the following link: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Fans Chassis: Five fans for front-to-rear cooling. N + 1 redundant. ■ Power supply: The power supply is equipped with a fan. ■ Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 8
Cisco 1225 virtual interface card. Notes . . . 1. NCSI = network communications services interface protocol. The slot stays active when the server is in standby power state. 2. CNIC = Cisco network interface card. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Table 2 PID of the C22 M3 High-Density SFF Rack Base Server Product ID (PID) Description UCSC-C22-M3S UCS C22 M3 SFF with rail kit, without PSU, CPU, memory, HDD, SSD, or PCIe cards The Cisco C22 M3 server: Includes a rail kit (UCSC-RAIL1) ■...
1. If higher or lower speed DIMMs are selected than what is shown in the table for a given CPU, the DIMMs will be clocked at the lowest common denominator of CPU clock and DIMM clock. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 12
For optimal performance, select DIMMs with the highest clock speed for a given processor ■ (see Table 3 on page 11). If you select DIMMs whose speeds are lower or higher than that shown in the tables, suboptimal performance will result. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Registered ECC DDR3 DIMMS (RDIMMS), unregistered DIMMs (UDIMMs), or load-reduced DIMMs (LRDIMMs) Memory is organized with three memory channels per CPU, with up to two DIMMs per ■ channel, as shown in Figure Figure 4 C22 M3 SFF Memory Organization Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 14
8GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v 1.35 V UCS-MR-1X162RY-A 16GB DDR3-1600-MHz RDIMM/PC3-12800/2R/x4/1.35v 1.35 V UCS-MU-1X042RE-A 4 GB DDR3-1333-MHz ECC UDIMM/PC3-10600/1R/x4/1.35v 1.35 V UCS-ML-1X324RY-A 32GB DDR3-1600-MHz LR DIMM/PC3-10600/4R/x4/1.35v 1.35 V Memory Mirroring Option N01-MMIRROR Memory mirroring option Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 15
2 DIMMs in Channel F Select the memory mirroring option (N01-MMIRROR) as shown in Table 4 on page ■ NOTE: System performance is optimized when the DIMM type and quantity are equal for both CPUs. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 16
1 DPC: 1333 MHz is supported at 1.35 V and 1.5 V ■ 2 DPC: 1066 MHz is supported at 1.35 V and 1.5 V ■ For more information regarding memory, see CPUs and DIMMs, page Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
RAID (in this case, you must configure RAID yourself using separate software). (2) PCIe RAID controllers Cisco can provide factory-configured RAID systems depending on the RAID controller chosen and the number of drives ordered. Factory-configured RAID options are listed with each RAID card description.
Page 18
Supports up to 8 internal SAS+SATA drives. SAS and SATA drives can be ■ mixed. RAID levels supported: RAID 0, 1, 10 (see the RAID Configuration Options ■ section later in this table) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 19
Enable RAID 10 Setting. Requires an even number of drives (minimum of four drives) of the same size, speed, capacity. NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are supported for selected controllers as shown in Table Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 20
If you choose a PCIe RAID controller from Table 5 on page 18, it will be installed in slot 1 by default and you will not be able to select any optional PCIe card from Table 8 on page Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 21
2-CPU configuration, only the full-height PCIe card slot will be available for an additional optional PCIe card. Note that only a single Cisco UCS 1225 Virtual Interface Card (VIC) card is supported and it ■ must be installed in the full-length, full-height PCIe slot (slot 1) on riser 1, which is the only slot that supports NCSI.
NOTE: When creating a RAID volume, follow these guidelines: Use the same capacity for each drive in the volume ■ Use either all SAS drives or all SATA drives ■ Use either all HDDs or all SSDs ■ Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 23
Table 6 on page 18 or an embedded RAID option from Table 5 on page 18, or neither. If you select neither, the drives will be controlled by the embedded SATA-only RAID controller. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
N2XX-AQPCI05 Qlogic QLE2562, 8Gb dual port Fibre Channel HBA Half UCSC-PCIE-Q2672 Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics Half UCSC-PCIE-E16002 Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics Half Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 25
All PCIe cards will fit in either riser 1 or riser 2, except the VIC card, which must be installed ■ in the full-height slot of riser 1. The Cisco 1225 VIC card must be plugged into slot 1, which supports NCSI.
Page 27
Figure 5 on page 29 for typical SFP+ and twinax connections to the network cards. Caveats Check the table on the following page for compatibility between the PCIe network cards and SFPs or twinax cables. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Plug: NEMA 6-15P Connector: IEC60320/C13 CAB-AC-L620-C13 AC Power Cord, NEMA L6-20 - C13, 2M/6.5ft CAB-C13-CBN CABASY,WIRE,JUMPER CORD, 27" L, C13/C14, 10A/250V CAB-C13-C14-2M CABASY,WIRE,JUMPER CORD,PWR, 2 Meter, C13/C14, 10A/250V CAB-C13-C14-AC CORD,PWR,JMP,IEC60320/C14,IEC6 0320/C13, 3.0M Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 31
Cordset rating 16A, 250V Plug: (2500mm) EL 208 Connector: EL 701 SFS-250V-10A-IS Power Cord, SFS, 250V, 10A, Israel Cordset rating 10A, 250V/500V MAX (2500 mm) Connector: EL 701B Plug: (IEC60320/C13) EL 212 (SI-32) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 32
Cordset rating 13A, 125V (8.2 feet) (2.5m) Plug: Connector: NEMA 5-15P IEC60320/C15 CAB-250V-10A-BR Power Cord - 250V, 10A - Brazil 76.2 From Plug End 2,133.6 ± 25 CAB-JPN-3PIN Power Cord 3PIN, Japan Image not available Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
650 W power supply. The UCS Power Calculator can be found at the following link: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Table 13 Power Supply PIDs Product ID (PID) PID Description UCSC-PSU-450W 450 W power supply UCSC-PSU-650W 650 W power supply Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
NOTE: If you order and install a cable management arm, you will need the longest power cable available. For more information about the cable management arm, see the Cisco UCS C22 M3 Installation and Service Guide at this URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C22/install/C22.pdf...
Table 15 Trusted Platform Module Product ID (PID) PID Description UCSX-TPM1-001 Trusted Platform Module NOTE: The module used in this server conforms to TPM v1.2, as defined by the Trusted Computing Group (TCG). Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Table Table 16 USB 2.0 Drive Product ID (PID) PID Description UCS-USBFLSHA-8GB 8 GB Flash USB Drive for C22/C24 Figure 6 on page 48 for the location of the internal USB connector. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
MSWS-12-ST2S Windows Server 2012 Standard (2 CPU/2 VMs) MSWS-12-DC2S Windows Server 2012 Datacenter (2 CPU/Unlimited VMs) MSWS-12-ST2S-NS Windows Server 2012 Standard (2 CPU/2 VMs) No Cisco SVC MSWS-12-DC2S-NS Windows Server 2012 Datacenter (2 CPU/Unlim VM) No Cisco SVC SUSE SLES-SVR-2S-1G-1A SUSE Linux Enterprise Srvr (1-2 CPU,1 Phys);1yr Support Reqd...
Page 38
VSG-VLEM-UCS-1 VSG License Paper Delivery (1 CPU) for bundles UCS Director CUIC-PHY-SERV-BM-U Cisco Cloupia Resource Lic - One Phy Server node bare metal CUIC-PHY-SERV-U Cisco Cloupia Resource Lic - One physical Server node CUIC-TERM Acceptance of Cisco Cloupia License Terms...
Page 39
VMware vCenter 5 Server Standard, 3 yr support required VMW-VC5-STD-4A VMware vCenter 5 Server Standard, 4 yr support required VMW-VC5-STD-5A VMware vCenter 5 Server Standard, 5 yr support required UCS-VMW-TERMS Acceptance of Terms, Standalone VMW License for UCS Servers Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Windows Svr 2008 R2 EN (1-8CPU, 25CAL), Media MSWS-08R2-DCHV-RM Windows Svr 2008 R2 DC (1-8CPU, 25CAL), Media MSWS-12-ST2S-RM Windows Server 2012 Standard (2 CPU/2 VMs) Recovery Media MSWS-12-DC2S-RM Windows Server 2012 Datacenter (2 CPU/Unlimited VM) Rec Media Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
SMARTnet for UCS For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS Service. This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around the clock, from anywhere in the world.
Page 42
For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty, Cisco offers the Cisco SMARTnet for UCS Hardware Only Service. You can choose from two levels of advanced onsite parts replacement coverage in as little as four hours. SMARTnet for UCS Hardware Only Service provides remote access any time to Cisco support professionals who can determine if a return materials authorization (RMA) is required.
Page 43
CONFIGURING the SERVER Partner Support Service for UCS provides hardware and software support, including triage support for third party software, backed by Cisco technical resources and level three support. Table Table 21 Partner Support Service for UCS Service Product ID (PID)
Page 44
With the Cisco Unified Computing Drive Retention (UCDR) Service, you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive. In exchange for a Cisco replacement drive, you provide a signed Certificate of Destruction (CoD) confirming that the drive has been removed from the system listed, is no longer in service, and has been destroyed.
Page 45
UCWD5 8x5xNBD Onsite CON-UCWD5-C22M3S Retention For more service and support information, see the following URL: http://www.cisco.com/en/US/services/ps2961/ps10312/Unified_Computing_Services_Overview.pdf For a complete listing of available services for Cisco Unified Computing System, see this URL: http://www.cisco.com/en/US/products/ps10312/serv_group_home.html Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
OPTIONAL STEP - ORDER RACK(s) The optional R42610 rack is available from Cisco for the C-Series servers, including the C22 M3 SFF server. This rack is a standard 19-inch rack and can be ordered with a variety of options, as...
OPTIONAL STEP - ORDER PDU OPTIONAL STEP - ORDER PDU An optional power distribution unit (PDU) is available from Cisco for the C-Series rack servers, including theC22 M3 server. This PDU is available in a zero rack unit (RU) style (see Table 25).
(channels A, B, and C) are associated with CPU 1, while the DIMM slots on the bottom (channels D, E, and F) are associated with CPU 2. Bank 1 slots (blue) are populated before Bank 2 slots (black). Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 50
SUPPLEMENTAL MATERIAL Figure 7 Physical Layout of CPU DIMM Channels and Banks CPU1 CPU2 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
8 GB DIMMs and black slots with 4 GB DIMMs and total memory size should be 12 GB for each of the 3 channels for both CPUs. — When mixing DIMMs, all the DIMMs in the server must be the same speed. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
2 DPC while maintaining the maximum memory speed at 1600 MHz. 12 x 8GB gives the peak performance for this configuration and is recommended if there is no plan of increasing the total memory in the future. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage DIMMs. CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage ■ DIMMs operating in Power Saving Mode only, and do not support Performance Mode. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
BIOS and enable the OPROM for the desired slot and disable the OPROM for the default PCIe slot (see Figure 8 on page 56). 4. The 9220-4i RAID controller card supports up to 4 drives. All other RAID controller cards support up to 8 drives. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
ROM with which it can boot up devices. Go into the BIOS and disable the OPROM on the PCIe slots not used for booting so that resources are available for the slots that are used for booting. An example OPROM BIOS screen is shown in Figure Figure 8 Example BIOS Screen for OPROM Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
SUPPLEMENTAL MATERIAL RACKS The Cisco R42610 rack (see Figure 9) is certified for Cisco UCS installation at customer sites and is suitable for the following equipment: Cisco UCS B-Series servers and fabric interconnects ■ Cisco UCS C-Series and select Nexus switches ■...
Page 58
SUPPLEMENTAL MATERIAL Figure 9 Cisco R42610 Rack Front view - door closed Front view - door open Front view - door removed Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
With a Cisco RP Series PDU in the rack, you can replace up to two dozen input power cords with just one. The fixed input cord connects to the power source from overhead or under-floor distribution. Your IT equipment is then powered by PDU outlets in the rack using short, easy-to-manage power cords.
CIMC and some motherboard functions) On (green) Card power is on Unit ID Unit ID not active (LED is integrated into On (blue) Unit ID is activated unit ID button) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 62
Blinking (amber) One or more power supplies are in a critical fault state. Network Link Status Undefined On (green) Link pulses detected on any of the LOM ports, but no activity. Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
10/100/1000 Ethernet dedicated management link status LED Power supply AC OK LED 10/100/1000 Ethernet dedicated management link speed LED 1-Gb Ethernet link speed LED Rear Identification button/LED 1-Gb Ethernet link status LED — — Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
Page 64
On (amber) Link Speed = 100 Mbps On (green) Link Speed = 1 Gbps Unit ID Unit ID not active (LED is integrated into On (blue) Unit ID is activated unit ID button) Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
23.48 lbs (10.65 kg) Power Specifications The general power specifications for the C22 M3 SFF server 450 W power supply are listed in Table Table 34 UCS C22 M3 SFF 450 W Power Supply Specifications Description Specification AC input voltage...
Page 66
Standby power: 12 VDC Power supply efficiency CSCI Platinum NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet. For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL: https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...
47CFR Part 15 (CFR 47) Class A AS/NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000-3-2 EN61000-3-3 KN22 Class A CNS13438 Class A EMC - Immunity EN55024 CISPR24 EN300386 KN24 Cisco UCS C22 M3 High-Density SFF Rack-Mount Server...