TECHNICAL SPECIFICATIONS
The general power specifications for the C22 M3 SFF server 650 W power supply are listed in
Table 35 UCS C22 M3 SFF 650 W Power Supply Specifications
Description
AC input voltage
AC input frequency
Maximum AC input current
Maximum AC inrush current
Maximum output power for the
power supply
Power supply output voltage
Power supply efficiency
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
https://express.salire.com/Go/Cisco/Cisco-UCS-Power-Calculator.aspx
66
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.
Specification
90 to 264 VAC self-ranging,
100 to 120 VAC nominal
200 to 240 VAC nominal
Range: 47 to 63 Hz (single phase, 50 to 60 Hz nominal)
7.6 A maximum at 100 VAC
3.65 A maximum at 208 VAC
11 A peak @ 35° C, 208 VAC
650 W
Main power: 12 VDC
Standby power: 12 VDC
CSCI Platinum
NOTE: AC input connector is an IEC 320 C-14 15A/250VAC power inlet.