Table 6 Available Hardware RAID Options (continued)
Product ID (PID)
UCSC-RAID-9220-4i
UCS-RAID9270CV-8i
RAID Configuration Options (not available for embedded RAID)
R2XX-RAID0
R2XX-RAID1
R2XX-RAID5
R2XX-RAID6
R2XX-RAID10
Cisco UCS C22 M3 High-Density SFF Rack-Mount Server
PID Description
LSI MegaRAID 9220-4i
Supports up to four internal SAS+SATA drives. SAS and SATA drives can be
■
mixed.
RAID levels supported: RAID 0, 1, 10 (see the RAID Configuration Options
■
section later in this table)
LSI MegaRAID 9270CV-8i (with supercap power backup)
Supports up to 8 internal SAS+SATA drives. SAS and SATA drives can be
■
mixed.
Includes a 1 GB Transportable Memory Module (TMM) cache and
■
chassis-mount (remote) supercap power module for data cache backup
RAID levels supported: RAID 0, 1, 5, 6, 10, 50, 60 (see the RAID
■
Configuration Options section later in this table)
Factory preconfigured RAID striping option
Enable RAID 0 Setting. Requires a minimum of one hard drive.
Factory preconfigured RAID mirroring option
Enable RAID 1 Setting. Requires exactly two drives with the same size, speed,
capacity.
Factory preconfigured RAID option
Enable RAID 5 Setting. Requires a minimum of three drives of the same size,
speed, capacity.
Factory preconfigured RAID option
Enable RAID 6 Setting. Requires a minimum of four drives of the same size,
speed, capacity.
Factory preconfigured RAID option
Enable RAID 10 Setting. Requires an even number of drives (minimum of four
drives) of the same size, speed, capacity.
NOTE: Although RAID levels 50 and 60 are not orderable from the factory, they are
supported for selected controllers as shown in
CONFIGURING the SERVER
Table
6.
19