11 . Room Temperature Offset (+9°F to -9°F) (+4 .5°C to -4 .5°C)
Adjust to calibrate displayed room temperature to match actual room
temperature .
Note: When not set to 0, will display .
Press the up or down button to select .
Press the right button to advance to the next screen .
12 . Maximum Cycles Allowed Per Hour (- -, 2-6)
- - = as many as needed, 2-6 = maximum cycles/hour
Press the up or down button to select .
Press the right button to advance to the next screen .
13 . Temperature Sensor (1-4)
1 . Only on-board sensor determines room temperature .
2 . Only remote sensor determines room temperature .
3 . Average temperature of on-board and remote sensor .
4 . Only on-board sensor will be used until NITE period, and then only
remote sensor is used .
Note: If there is no remote sensor, option 1 must be selected .
Press the up or down button to select .
Press the right button to advance to the next screen .