Technical Specificatons - Power; Unit Environment And Operating Conditions; Power Supply - HP EliteDesk 800 G1 Series Quickspecs

Elitedesk 800 g1 series business desktop
Hide thumbs Also See for EliteDesk 800 G1 Series:
Table of Contents

Advertisement

QuickSpecs
Technical Specifications – Power

Unit Environment and Operating Conditions

General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the enclosure,
and the same operating guidelines listed above will still apply.
Temperature Range
Relative Humidity
Maximum Altitude
(unpressurized)
*Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained sunlight.
Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.

Power Supply

Standard Efficiency
High
Efficiency*
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency
Range
Rated Input Current
Rated Input Current with
Energy
Efficient*
Power Supply
Current Leakage
(NFPA 99)
Power Supply Fan
Power cord length
External Power Adapter
Dimensions
Operating: 50° to 95° F (10° to 35°
Non-operating: –22° to 140° F(–30° to 60° C)
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
USDT
N/A
Integrated
135W active
graphics:
PFC 87%
efficient
Discrete
180W active
graphics:
PFC 87%
efficient
90 - 264 VAC
100 - 240 VAC
50/60 Hz
47 – 63 Hz
N/A
135W: 2.4A
180W: 2.9A
< 250 µA
N/A
N/A
6.7 x 2.6 x 1.5 in
DA - 14653 North America — Version 5 — July 18, 2013
HP EliteDesk 800 G1 Series Business Desktop
C)*
SFF
240W active PFC
240W active PFC
87/90/87% efficient at
20/50/100% load
240W active PFC
90/92/89% efficient at
20/50/100% load
90 - 264 VAC
100 - 240 VAC
50/60 Hz
47 – 63 Hz
4A
4A
< 275 µA
92=>70mm variable speed
6.0 ft. (1.83 m)
N/A
TWR
320W active PFC
320W active PFC
87/90/87% efficient at
20/50/100% load
320W active PFC
90/92/89% efficient at
20/50/100% load
90 - 264 VAC
100 - 240 VAC
50/60 Hz
47 – 63 Hz
5.5A
5.5A
<450=>275uA
92mm variable speed
6.0 ft. (1.83 m)
N/A
Page 54

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents