Lenovo ThinkStation Hardware Maintenance Manual page 82

Machine types: 4105, 4157 and 4217, 4155, 4158 and 4218
Hide thumbs Also See for ThinkStation:
Table of Contents

Advertisement

76
Hardware Maintenance Manual
Diagnostic Error Code
018-197-XXX
PCI Card test warning
018-198-XXX
PCI Card test aborted
018-199-XXX
PCI Card test failed, cause unknown
018-250-XXX
PCI Card Services error
020-000-XXX
PCI Interface Test Passed
020-0XX-XXX
PCI Interface error
020-195-XXX
PCI Test aborted by user
020-196-XXX
PCI test halt, error threshold exceeded
020-197-XXX
PCI test warning
FRU/Action
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Flash the system and re-test. See "Flash
update procedures" on page 253
3. Go to "Undetermined problems" on page
91
1. Go to "Undetermined problems" on page
91
2. Flash the system and re-test. See "Flash
update procedures" on page 253
3. Replace component under function test
1. PCI card
2. Riser card, if installed
3. System board
No action
1. PCI card
2. Riser card, if installed
3. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test