Rec Y Current Adjustment (Vc-251 Board) - Sony CCD-TR618 Service Manual

Video camera recorder
Hide thumbs Also See for CCD-TR618:
Table of Contents

Advertisement

6. REC Y Current Adjustment (VC-251 board)

Adjust the Y FM signal recording current.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
REC RF (Pin qg of CN713 or Pin qg
of CPC connector of FP-262 flexible)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
6A, 6B
Specified Value
A=235 ± 5mV (NTSC)
A=280 ± 5mV (PAL)
Note1: Don't disconnect the DC power supply of the camcorder during
the following adjustments.
When the following symptom occurs, reset the data of D page to
the values written down.
1) The power is shut off so that unit cannot operate.
0.18 sec
Fig. 5-3-9.
Adjusting method:
Order Page Address Data
1
2
3
4
7
5
F9
6
7
8
9
10
11
12
A
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
Note2: Use the REC buttons of the adjustment remote commander (with
Note3: Refer to "Table 5-4-1. Hexadecimal-decimal Conversion Table".
5-44
Set to the stop mode.
0
01
01
Set the data.
D
14
Write down the data.
D
14
Set the following data, and press
PAUSE button.
06 (NTSC), 26 (PAL)
D
15
Write down the data.
D
15
Set the following data, and press
PAUSE button.
6D (NTSC), 6F (PAL)
Set to VTR recording mode.
(Note2)
E
FB
Write down the data.
E
FB
06
Set the data, and press PAUSE
button.
F
71
Write down the data.
F
71
00
Set the data, and press PAUSE
button.
2
01
41
Set the data, and press PAUSE
button.
6
63
01
Set the data.
F
6B
Change the data and set the Y
signal level (A) to the specified
value, and press PAUSE button.
F
6B
Read the data, and this data is
named D
F
6A
D
Set the data, and press PAUSE
6B
button.
Convert D
and obtain D
Calculate D
equations (Decimal calculation)
When D
When D
Convert D
number, and obtain D
7
F9
D
Set the data, and press PAUSE
F9
button.
6
63
00
Set the data.
2
01
00
Set the data, and press PAUSE
button.
F
71
Set the data written down at step
10, and press PAUSE button.
E
FB
Set the data written down at step
8, and press PAUSE button.
D
14
Set the data written down at step
3, and press PAUSE button.
D
15
Set the data written down at step
5, and press PAUSE button.
0
01
00
Set the data.
the HOLD switch set in the OFF position).
Ver 1.1 2001. 04
Procedure
.
6B
to decimal notation,
6B
'. (Note3)
6B
' using following
F9
' 243
6B
D
' = D
' + 12
F9
6B
'> 243
6B
D
' = 255
F9
' to a hexadecimal
F9
. (Note3)
F9

Hide quick links: