11. Angular Velocity Sensor Sensitivity Adjustment

(CCD-TR818/TRV68/TRV78/TRV78E/TRV88/TRV98/

TRV98E)

Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03JA
Type B: ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing, re-
adjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
5E, 5F
Specified Value
2700 to 5100
Note1: Displayed data of the adjustment remote commander.
1 : XX : XX
Note2: MI-040 board: CCD-TR818
MI-041 board: CCD-TRV68/TRV78/TRV78E/TRV88/TRV98/
TRV98E
Switch setting:
1)
STEADY SHOT (Menu display) ...................................... ON
2)
ZOOM .......................................................................... Center
Adjusting method:
Order Page Address Data
1
0
01
01
2
F
5E
3
F
5F
4
0
03
11
5
1
6
0
03
12
7
1
Processing after Completing Adjustments
Order Page Address Data
1
0
01
00
2
0
03
00
3
Display data
Procedure
Set the data.
Set the following data, and press
PAUSE button.
5A (NTSC), 74 (PAL)
Set the following data, and press
PAUSE button.
57 (NTSC), 5D (PAL)
Pitch sensor check
(MI-040/041 board SE751)
Set the data.
Check that the display data (Note1)
satisfies the specified value.
Yaw sensor check
(MI-040/041 board SE752)
Set the data.
Check that the display data (Note1)
satisfies the specified value.
Procedure
Set the data.
Set the data.
Move the camcorder, and check
that the steady shot operations
have been performed normally