Check Out The System - Honeywell MAGICSTAT CT3300 Installation And Programming Instructions

Weekday/weekend (5-day/2-day) programmable heat and/or cool low voltage (20 to 30 vac) thermostat and mounting plate
Table of Contents

Advertisement

b.
Set the System switch to COOL.
c.
Repeat steps 3c. through 3k. to program the weekday and weekend cooling schedule.
Step 5. Check out the system
Verify that your heating system works
a.
Set the System switch to HEAT and the Fan switch to AUTO.
b.
Press
until the setting is 10 ° F (6 °C) above room
temperature (Fig. 25).
Your heating system should start and the fan should run after a
short delay.
c.
Press
until the setting is 10 ° F (6 °C) below room
temperature.
Your heating system should shut off.
Verify that your cooling system works
IMPORTANT: To avoid damaging the compressor in the air
conditioner, do not operate the cooling system when the
temperature outdoors is below 50°F (10°C).
d.
Set the System switch to COOL and the Fan switch to AUTO.
e.
until the setting is 10 ° F (6 °C) below room
Press
temperature (Fig. 26).
Your cooling system and fan should start.
Note: When the cooling setting is changed, the thermostat may
delay up to 5 minutes before turning on the air conditioner. This
delay protects the compressor.
16
PROGRAMMING
Fig. 25
Fig. 26
69-0654-5

Hide quick links: