Installer Self-Test - Honeywell Chronotherm IV T8601D Installation Instructions Manual

Deluxe programmable thermostat
Hide thumbs Also See for Chronotherm IV T8601D:
Table of Contents

Advertisement

INSTALLER SELF-TEST

Use the Installer Self-Test to check the thermostat oper-
ation. Refer to Table 4 for a list of the available self-tests.
CAUTION
Equipment Damage Hazard.
Minimum compressor off-time is bypassed
during Installer System Test.
Avoid cycling compressor quickly.
To start the self-test:
Press and hold the increase ! and decrease " keys at
the same time until 10 appears. All segments of the
display are displayed before the 10 appears. See Fig. 12
and 13.
Table 4. Tests Available In The Installer Self-Test.
Test
Number
System Test Description
10-19
Heating equipment can be turned on and off
30-39
Cooling equipment can be turned on and off
40-49
Fan equipment can be turned on and off
60 0 to
Keyboard keys test
60 19
70-79
Thermostat information including date code
and software versions are displayed
Wait
Set Program
Set Day/Time
Recovery
Hold for
Em Ht
Aux Ht
Filter
Days
Mon
Tue Wed Thu Fri Sat Sun
Wake Leave Return Sleep
Fig. 12. Display of all LCD segments.
Fig. 13. Display of test number.
T8601D CHRONOTHERM® IV DELUXE PROGRAMMABLE THERMOSTATS
Temporary Setting
AM
PM
Room
Outdoor
Repl Batt
Heat Cool
DST
Refer to Table 5 for the directions and results of the
specific tests.
NOTE: Press Time
Time
Run Program to exit the self-test.
Key to
Press
Number
Heating Equipment System Test
Time
!
"
Cooling Equipment System Test
Time
!
"
Fan Equipment System Test
Time
!
"
Key Equipment System Test
Em Heat
Off
Time
Cool
Auto
F F an
On
NOTE: Press any key and the displayed numbers
Auto
change. Press Time
M14559
and Time
Program key does not exit this test. Press
Time or Time
to exit.
M14612
9
to advance to the next test and
to go back to the previous test. Press
Table 5. Installer Self-Test Options.
Test
Description
10
Enter heating equipment system test
11
Heat comes on. When Installer Setup
number 2 is 1, the system fan is also
energized
10
Heat and system fan turn off
30
Change from heating to cooling
equipment system test
31
Cool and system fan come on
30
Cool and system fan turn off
40
Change from cooling to fan
equipment system test
41
Fan comes on
40
Fan turns off
60
Change from fan to key operation
system test
to go to the previous test
to go to the next test. The Run
and then the Run Program key
69-1410—2