Fan Motor Control - Oki OKIPAGE 10ex Troubleshooting Manual

Led page printer
Hide thumbs Also See for OKIPAGE 10ex:
Table of Contents

Advertisement

3.10

Fan Motor Control

The stop/rotation of the fan motor is controlled by FANON1-P and FANON2-N signals. When the
fan motor rotates normally, FANALM-P signal generated in the hole element built in the fan motor
is input to the CPU.
FANON1-P
109
CPU
FANON2-N
126
FANALM-N
110
FANON1-P
FANALM-P
FAN MOVE
Fan motor start: Initial request, heater on, print start request
Fan motor stop: •
Main (drum) motor
Heater control
Fan motor
40990901TH Rev.1
TR503
3
5V
0V
38V
8VR
5V
339/2901
IC10
0V
0V
FANON1-P
FANON2-N
H
L
H
H
L
X
The motor immediately stops when an engine error or a fan error occurs.
The motor stops 0 second or 20 minutes after the occurrence of a paper jam, size
error, or fuse error.
The motor stops in the power save mode as below.
ON
ON
Heater
hold time
8 min. or
0 sec.
38V
R554
TR504
1
TR502
3
TR501
Fan motor rotation
Normal speed
Half speed
STOP
0.7 sec max
Lock
OFF
30 sec.
Rotation state
FAN
Fan Motor
1
M
2
3
0V
OFF
Stop state
22 /

Advertisement

Table of Contents
loading

Table of Contents