Arc Lamp Assembly - Hughes JVC 100 Service Manual

Hughes jvc 100 projector service manual
Hide thumbs Also See for 100:
Table of Contents

Advertisement

Chapter 4---Maintenance (Removal/Replacement)
filters should be cleaned more frequently. To clean the filters, remove, vacuum
out or blow the filters with compressed air.
One filter is a foam filter located in the rear of the projector.
!
The other filter is located on the on the bottom left side of the projector,
!
just in front of the HVPS.

4.4 Arc Lamp Assembly

The Arc Lamp Assembly consists of a Xenon Arc Lamp, a Docking Module, a
light shield and an Arc Lamp cooling duct. The Arc Lamp fits inside the Docking
Module.
CAUTION!:
current be turned down (see Section 3.1) before installing a new Arc
Lamp to help prevent possible damage that could reduce the life of the
new lamp.
WARNING!!!
projector. Before proceeding with the removal of any subassemblies
below, always:
Turn the projector off, allow the projector to cool for 5 minutes.
!
Power off the main ac circuit breaker at the front right corner of the
!
projector
Remove the power plug from the AC outlet.
!
To remove the Arc Lamp Docking Module:
Model 100 Service Manual
Figure 4-3 Air Filter (bottom left side).
It is strongly recommended that the Arc Lamp
Dangerous light exists in this area of the