Default Values - Datalogic Heron D110 Quick Reference Manual

For ibm 46xx terminals
Hide thumbs Also See for Heron D110:
Table of Contents

Advertisement

DEFAULT VALUES

RS232 DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking,
delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO
enabled, serial trigger lock disabled;
DATA FORMAT
code length not transmitted, no header, terminator = CR-LF,
character replacement disabled
IBM DEFAULT SETTINGS
DATA FORMAT
header, no terminator
POWER SAVE
scan rate max, standby disabled, sleep disabled
READING PARAMETERS
hardware trigger, trigger active level, no trigger timeout,
Flash On = 1 sec, Flash Off = .6 sec, one read per cycle,
safety time .5 sec, beeper intensity high, tone 2, beeper type
monotone, beeper length short, good read spot duration
medium,
operation aiming light enabled
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit
control enabled, Puzzle Solver™ disabled, decoding safety =
one read
CODE SELECTION
Enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
Interleaved 2/5
check digit control and transmission, variable length
code; 4-99 characters
Standard Code 39
no check digit control, variable length code; 1-99
characters
Code 128
variable length code; 1-99 characters
Disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical
codes, MSI, Plessey, Telepen, Delta IBM, Code 11,
Code 16K, Code 49, RSS Codes
ADVANCED FORMATTING PARAMETERS*
concatenation disabled, no advanced formats defined
* The advanced formatting parameters may not be compatible
with the IBM 46xx cash register parameters.
: code identifier disabled, no field adjustment,
: IBM Standard, code identifier disabled, no
stand
recognition
beep
enabled;
automatic

Advertisement

Table of Contents
loading

Table of Contents