SYSTEM DEFAULTS
All lines are DTMF
Voice signalling attempted first when inter-
com call is made
1 sec. pause time
2 sec. dial tone recall time
30 sec. recall from hold
All lines prfvate
All lines are CO lines
No toll restriction set
Printer port set for 110 baud data rate
2 sec. automatic pause insertion wait time
PROCEDURE
NOTE: Before performing this procedure, turn
to the System COS Programming Reference
Chart (Table 3-l), locatedat the end of this chap
it.
1.
Press tTCM ++ 7 4 6 +K (base level entry)
Select the
2.
PULSE/TONE
system default characteristics.
Press #. Dial tone will stop.
l
Press 0 to select
l
Press 1 to sgct
l
Press *. Dial tone will return.
l
NOTE: In addition to setting the dialing mode,
the above action defaults the system, line and
station COS.
3. Select Intercom slgnalling
when intercom call is placed.
Press Al3 for tone signalling.
l
-or-
.
Press Al4 for voice signalling.
Press *.
l
4 . Select time interval for programmed pause.
Press 4. Dial tone will stop.
l
Press key to select time interval per
l
chart. Tone burst confirms selection.
Press f. Dial tone will sound.
l
PROGRAMMING PROCEDURE
or TONE ONLY dialing
TONE ONLY.
PULSE/TONE.
first performed
3-3
5. Select pulse dial operatlng characteristics.
Press 5. Dial tone will stop.
l
Press keypad key to select operating
l
characteristic per chart. Tone burst con-
firms selection.
PULSES PER SECOND I BREAK/MAKE RATIO
1
10 PPS
2
20 PPS
Press the % key. Dial tone will sound.
6.
flash/dial tone recall time
Select
Press 6. Dial tone will stop.
l
Press keypad key to select time interval
l
Press *. Dial tone will sound.
l
hold
time
7 . Select
recall
Press 7. Dial tone will stop.
l
Press keypad key to select hold recall in-
l
terval from chart.
NOTE: The Q program selection makes It pos-
sible for an exclusive hold condition, when set
at a station, to place a line on a pennanent hold
thaf cannot be released at any other station.
System
Programming
I
interval.
interval.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ExecuTech 0616 Series and is the answer not in the manual?

This manual is also suitable for:

Executech 0816

Table of Contents