Operating Method - Inter-m Z-500 Operation Manual

Zone output selector
Table of Contents

Advertisement

Operating Method

Operating Method
1. A BASIC BROADCASTING SETTING UP
1) Select a desired BUS among BUS of 6 channels to broadcast by pressing BUS select switch of each
zone. Bus is sequentially selected to the order of 1,2,3,4,5,6,-,1,2,3,4,5,6,-
2) Institute sound volume of desired lever by controlling a relevant output volume of each zone.
3) In case of controlling BUS and VOLUME of each zone by using local controller L-500, setting in local
area by pressing the WALL Button of relevant zone.
4) In case of broadcasting timer Alarm or paging, timer Alarm or paging broadcasting can be done
to desired zone by controlling output selection switch of timer Alarm/paging broadcasting on the
rear side.
2. CONNECTING L-500
1) Connect with L-500 connection terminal on the rear side of Z-500 using Category5(UTP) material.
2) Connection hole number of the connected Z-500 represents output zone and assure connection up to
Maximum 300m.
3) Connection of total 21 sets of L-500 is permitted to a piece of Z-500.
4) Without need of setting separate ID, automatic recognition is done together with Z-500 and immediate
use is permitted.
5) Selected BGM number is displayed in the relevant zone after 0, 1, 2, 3, 4, 5, 6, 7, 8, A, B, C, D, E, F is
orderly displayed on the BGM display window of L-500 if power is supplied.
6) BUS selection and BUS output sound volume of Z-500 can be controlled by using L-500 if dot (.) is
displayed on the BUS display window of L-500.
7) Control power of L-500 is endowed or released by using the Wall ENABLE button on the front side of
Z-500. If Wall ENABLE is endowed to L-500, the Enable button of Z-500 turns on, and dot (.) is
displayed on the BGM display window of L-500.
8) If 'E' flicker continually on the display window, check connection status and unit.
Since sound volume is set to minimum in initial use, turn volume of encoder clockwise until change of
sound volume is confirmed.
3. CHANGE OF BUS AND CONTROL OF OUTPUT ZONE SOUND USING L-500
1) Endow control power of L-500 by pressing the Wall Enable button of Z-500.
2) Check that BUS number is changed by operating the BUS Select Button of L-500.
3) Same BUS number is displayed on the front BUS display window of Z_500 and the display window
of L-500.
4) Control a sound volume of output zone by using a sound volume control encoder.
The volume control encoder of L-500 and volume on the front side of Z-500 unit are used to control
sound volume of the BUS broadcasting in the output zone. Paging MIC broadcasting and the output
zone sound volume of RM-500 are not controlled with encoder and volume.
4. SELF-LOCAL BGM AND MIC BROADCASTING USING L-500
Zone self-broadcasting is permitted with L-500. You can perform desired MIC broadcasting in respective
zone or listen to BGM music as well as main BGM connected to Z-500.
LOCAL BGM&MIC broadcasting of L-500 has higher priority than main BGM of Z-500 and thus main
BGM automatically becomes mute during self-broadcasting of L-500.
1) Connect desired MIC or sound source unit to MIC or line input.
2) Control sound volume by using each input sound volume control volumes.
3) Immediate broadcasting is possible and the zone output sound volume can be controlled by using
encoder of L-500 or a volume of Z-500.
ZONE OUTPUT SELECTOR
9
Z-500

Advertisement

Table of Contents
loading

Table of Contents