System Messages

Error Messages

Error Message
Description
Address mark not
The BIOS found a faulty disk sector or could not find a particular disk sector.
found
Alert! Previous
The system failed to complete the boot routine three consecutive times for the same error.
attempts at booting
Contact Dell and report the checkpoint code (nnnn) to the support technician.
this system have
failed at checkpoint
[nnnn]. For help in
resolving this
problem, please note
this checkpoint and
contact Dell
Technical Support.
Alert! Security
The MFG_MODE jumper has been set and AMT Management features are disabled until it is
override Jumper is
removed.
installed.
Attachment failed to
The floppy or hard-drive controller cannot send data to the associated drive.
respond
Bad command or file
Ensure that you have spelled the command correctly, put spaces in the proper place, and used
name
the correct pathname.
Bad error-correction
The floppy or hard-drive controller detected an uncorrectable read error.
code (ECC) on disk
read
Controller has failed
The hard drive or the associated controller is defective.
Data error
The floppy or hard drive cannot read the data. For the Windows operating system, run the
chkdsk utility to check the file structure of the floppy or hard drive. For any other operating
system, run the appropriate corresponding utility.
Decreasing available
One or more memory modules may be faulty or improperly seated. Re-install the memory
memory
modules and, if necessary, replace them.
Diskette drive 0 seek
A cable may be loose or the system configuration information may not match the hardware
failure
configuration.
Diskette read failure
The floppy disk may be defective or a cable may be loose. If the drive access light turns on, try
a different disk.