APPLICATIONS

WARNING 
* The recirculation pump is to be controlled by:
‐Dual‐set aquastat (recommended w/timer) 
OR 
‐"Pump Control Mode" (T‐D2 Models only). 
Refer to p. 23. 
* The recirculation pump is to provide no less 
than 2 GPM and no more than 4 GPM through 
each activated unit in the system. 
Hot water outlet to 
fixtures 
 
‐Space‐Heating Applications‐ 
In order to purge air in water pipes within a closed‐loop system, an air vent 
and air separator should be installed in to the system.  Required circulation 
flow  rates  are  labeled  next  to  each  application  diagram.    These  flow  rate 
requirements must be followed. 
Toxic chemicals used in boiler treatments such as alcohol, glycerol and glycol 
groups must not be introduced into the system if the system incorporates an 
open‐loop potable water system. 
The water heater can be used to supply potable water and space heating and 
shall  not  be  connected  to  any  heating  system  or  component(s)  previously 
used with non‐potable water where any chemicals were added to the water 
heating appliances. 
When  the  system  requires  water  for  space  heating  at  temperatures  higher 
than  required  for  other  uses,  a  means  such  as  a  mixing  valve  shall  be 
installed to temper the water for those other uses in order to reduce scald 
hazard potential. 
Water  temperature  over  125  °F  (52°C)  can  cause  severe  burns  instantly  or 
death from scalds. 
Chemicals such as diluted Glycol can be used for radiant floor, Hydro/fan coil 
air  or  Baseboard  heating  only.  The  diluted  solution  of  glycol  must  contain 
between 25 and 55 % of Glycol. Be aware that in closed‐loop glycol systems, 
low  pressure  in  the  heat  exchanger  can  cause  low‐temperature  boiling, 
resulting  in  excessive  noise  and  damage  to  the  water  heater.  Consult  with 
the glycol maker for specifications prior to use.    
‐Recirculation‐
Recirculation 
Air 
pump 
separator
This is a concept drawing only. 
 
Air Vent
S
Check valve
Check valve
28
 
Page
Installation 
Hot
Cold
Water
Water
Gas
Outlet
Inlet
Inlet
Unions 
Ball valves
Gas supply 
Expansion tank
Cold water 
inlet 
Y‐Strainer