WARNING: Before operating water heater, be sure tank is filled with
water. See "Safety Warnings".
A. This appliance does not have a pilot. It is equipped with an ignition device
which automatically lights the burner. Do not try to light the burner by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle on
the floor.

WHAT TO DO IF YOU SMELL GAS

 Do not try to light any appliance.
 Do not touch any electric switch.
 Do not use any phone in your building.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
 If you cannot reach your gas supplier, call the fire department.
C. This is an automatic gas valve, no adjustments are necessary. Do not attempt
to repair the gas valve. This may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call
a qualified service technician to inspect the appliance and to replace any part of
the control system and any gas control which has been under water.
E. Before operating water heater, check the location of the vent to make sure it
will not be blocked by the opening of any door on the trailer. If it can be blocked,
do not operate the water heater with the door open.

OPERATING INSTRUCTIONS

1. STOP! Read the safety information provided.
2. Turn off all electric power to the appliance.
3. Turn "OFF" gas supply.
4. Wait five minutes for gas to clear the area. If you smell gas then STOP!
Follow instructions in item B of the safety information. If you don't smell gas, go
to next step.
5. Turn "ON" gas supply.
6. Turn on electrical power to the appliance.
7. Turn switch to "ON" position. If the burner does not light, the system will
automatically attempt two more tries for ignition before lock-out.
NOTE: Each ignition cycle will have a 15 second purge before spark cycle if
system is a three try system.
8. If lockout occurs before main burner lights, turn switch to "OFF", wait five
seconds and turn switch to "ON" position. This will restart the ignition cycle. The
first start-up of the heater may require several ignition cycles before all air is
purged from the gas lines.
If the burner will not come on, the following items should be checked before
calling a service person.
1. Switch turned off.
2. Gas supply to heater is empty or turned off.
3. Reset button on ECO is tripped.
OPERATING INSTRUCTIONS
– Electric –
Electric water heaters are designed to operate with a minimum amount of service
problems; however, proper operation and care is essential.
By far the most common trouble with electric water heaters results from
energizing the water heater before it is filled with water. Even brief operation of
the electric element without water in the tank will burn-out the electric heating
element.
Before the electric element will operate, the switch located behind the water
heater door in the lower left corner of the control housing must be in the "ON"
position.
To energize the electric element, locate the Switch, Lamp and Plate assembly
inside the RV and turn the switch marked "ELECTRIC" to the "ON" position. The
water heater temperature will be regulated by the thermostat.

TO TURN OFF WATER HEATER

1. Turn switch to "OFF" position.
2. Turn off electrical power to the appliance.
3. Turn off gas supply.
4. If vehicle is to be stored or heater is going to be turned off while subject
to freezing temperature, drain water heater. (See "Draining and Storage
Instructions.")