Suburban SW10D Installation And Operation Manual

Direct vent gas water heater direct spark ignition (dsi)
Hide thumbs Also See for SW10D:

Advertisement

• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRIC SWITCH: DO NOT USE ANY PHONE IN YOUR VEHICLE.
• IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. FOLLOW THE GAS SUPPLIER'S
INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL
INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
DO NOT STORE OR USE GASOLINE OR OTHER COMBUSTIBLE MATERIALS OR LIQUIDS NEAR OR
ADJACENT TO THIS HEATER OR ANY OTHER APPLIANCE. THIS APPLIANCE SHALL NOT BE INSTALLED IN
ANY LOCATION WHERE FLAMMABLE LIQUIDS OR VAPORS ARE LIKELY TO BE PRESENT.
AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER.
INSTALLER: AFFIX THESE INSTRUCTIONS TO OR ADJACENT TO WATER HEATER.
OWNER: RETAIN THESE INSTRUCTIONS AND WARRANTY FOR FUTURE REFERENCE.
ALL TECHNICAL AND WARRANTY QUESTIONS SHOULD BE DIRECTED TO THE COMPANY
LISTED ON THE WARRANTY, OR RATING PLATE WHICH CAME WITH YOUR WATER HEATER.
Part Number 204671
3-24-09
INSTALLATION AND OPERATION MANUAL
DIRECT VENT
GAS WATER HEATER
DIRECT SPARK IGNITION (DSI)
SW10D • SW10DM • SW10DE • SW10DEM
SW12D • SW12DE • SW12DEM
SW16D • SW16DE • 16DEM
FOR INSTALLATION IN RECREATIONAL
VEHICLES AND MOBILE HOUSING
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
FREEZE WARNING
DRAIN HEATER IF SUBJECT TO FREEZING TEMPERATURES.
FOR YOUR SAFETY
MODELS
SUBURBAN MANUFACTURING COMPANY
676 Broadway Street
Dayton, Tennessee 37321
423-775-2131
www.rvcomfort.com

Advertisement

Table of Contents
loading

Summary of Contents for Suburban SW10D

  • Page 1 INSTALLATION AND OPERATION MANUAL DIRECT VENT GAS WATER HEATER DIRECT SPARK IGNITION (DSI) MODELS SW10D • SW10DM • SW10DE • SW10DEM SW12D • SW12DE • SW12DEM SW16D • SW16DE • 16DEM FOR INSTALLATION IN RECREATIONAL VEHICLES AND MOBILE HOUSING FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS •...
  • Page 2: Installation Requirements

    CAUTION: Do not install this appliance to where the vent terminates below a slide-out. This appliance is not to be installed under any overhang. It I. The module board on models SW10D, SW10DE, SW12D, SW12DE, SW16D must be free and clear of any type overhang.
  • Page 3: Heater Overview

    Figure 1 Figure 1A DOOR FRAME FRAMED OPENING DC JUNCTION BOX (SEE FIGURE NO. 1) CAULKING MODELS SW10D, DE SW12D, DE FRAMED OPENING SW16D, DE CAULK AROUND OPENING PLACE SCREW OR SUITABLE FASTENER AS SHOWN. DOOR FRAME WHEN INSTALLED MUST NOT OVERLAP ONTO SCREW HEAD OR FASTENER.
  • Page 4: Electrical Connections

    A. Applicable to following models: SW10D, SW10DE, SW10DM, SW10DEM SW12D, SW12DE, SW12DEM, SW16D, SW16DE, and SW16DEM. B. Refer to Figure 2 for location of D.C. junction box on models SW10D ,SW10DE SW12D, SW12DE, SW16D and SW16DE. Refer to Figure 4 and 5 for location of D.C.
  • Page 5: Installation Of Motor Aid Heat Exchanger

    CAUTION: Before applying the 120 VAC power to the water heater junction to prevent flow of combustion and ventilating air. box, be sure the switch for electric element is in the “OFF” position. 3. Check to be sure there is no flame present at burner orifice or burner whenever main gas valve is closed.
  • Page 6: Relief Valve

    To extend anode life, drain water from tank whenever RV is not being used. THERMOSTAT AND MANUAL RESET Avoid any extended time of non use with water in tank. MODELS SW10D, SW10DE, SW10DM AND SW10DEM SW12D, SW12DE and SW12DEM Also, refer to section on winterizing.
  • Page 7: Operating Instructions

    Follow instructions in item B of the safety information. If you don’t smell gas, go heater. to next step. 4. On Models SW10D, SW10DE SW12D, SW12DE, SW16D and SW16DE 5. Turn “ON” gas supply. disconnect all wires at module board.
  • Page 8 TO TURN OFF WATER HEATER 3. Turn off gas supply. 1. Turn switch to “OFF” position. 4. If vehicle is to be stored or heater is going to be turned off while subject to freezing temperature, drain water heater. (See “Draining and Storage 2.
  • Page 9: Replacement Parts List

    Screw 8mm - 4.0 x ½ Hex Washer Head (2 Required) ..........121943 121943 1/4 Loxit Nut (Manifold to Burner) ................171463 171463 Electrode Wire (Not Shown) SW10D, SW10DE, SW12D, and SW12DE ....232456 232456 Electrode Wire (Not Shown) SW16D and SW16DE.............232459 232459 Screw 10 x 1/4 (No Substitute) (2 Required)..............121577...
  • Page 10 PARTS LIST FOR MODEL SW10DM (Figures 15 and 16) Item Part Number Item Part Number Description SW10DM Description SW10DM Cover, Module Board ................090340 Electrode ....................232258 Cover Junction Box ................090344 Burner Assembly with orifice ..............010843 Screw 10-32 x 3/8 (Green) ..............121702 1/4 Loxit Nut (Manifold to Valve) ...............171463 Switch, Lamp and Plate Assembly ............
  • Page 11 PARTS LIST FOR MODEL SW10DEM, SW12DEM AND SW16DEM (Figures 17 and 18) Item Part Number Description SW10DEM Item Part Number SW12DEM Description SW10DEM SW16DEM SW12DEM Cover Module Board ................090340 SW16DEM Cover, Junction Box (12 V.D.C.) ............090344 Burner Assembly with orifice ................010843 Screw 10-32 x 3/8 (Green) ..............
  • Page 12 TWO YEAR LIMITED WARRANTY SUBURBAN RECREATIONAL VEHICLE WATER HEATER TWO YEAR LIMITED WARRANTY This Suburban product is warranted to the original purchaser to be free from defects in material and workmanship under normal use and maintenance for a period of two years from date of purchase whether or not actual use begins on that date. It is the responsibility of the consumer/owner to establish the warranty period. Suburban does not use warranty registration cards for its standard warranty.
  • Page 13 _________________________________________ D’ACHAT DATE ____________________________________ STOCK NUMÉRO www.rvcomfort.com _____________________________________ SÉRIE NUMÉRO 7101 Ext. 775-2131, (423) ___________________________________ MODÈLE NUMÉRO 37321 Tennessee Dayton, Street Broadway l’appareil descriptive l’information ci-dessous inscrire référence, Pour Department Service Customer Company Manufacturing Suburban contactez: fournie liste à vous référez proche, plus...
  • Page 14 Figure VIEW FRONT PLATE SERIAL & MODEL Figure VIEW REAR COLD 232791 ..SW16DEM) (SW12DEM, représenté) (Pas électrode 232454 ......(SW10DEM) représenté) (Pas électrode 171463 ................Loxit 121943 ....Exigées) Rondelle 010843 ........orifice avec brleur Assemblage 063444 ................. Support 232258 ................
  • Page 15 Figure L'AVANT VUEDE SÉRIE NUMÉRO MODÉLE NUMÉRO Figure L'ARRIÉRE VUEDE FROIDE CHAUDE ..........232454 représenté) (Pas électrode ................171463 Loxit L’écrou .............121577 Exigees) Bec................063444 Support ....121943 Exigées) Rondelle 232258 ................L’électrode ..........070989 L'admission Bague, 070874 ................Bague ..................232767 L'Anode 101777 ....Collecteur Tuyau Complet Assemblage...
  • Page 16 121577 121577 ............... Exigées) Substitution) (Pas 232459 232459 .............. SW16DE SW16D représenté) (Pas électrode 232456 232456 ......SW12DE SW12D, SW10DE, SW10D, représenté) (Pas électrode 171463 171463 ........................... Loxit 171463 171463 ........................... Loxit 063444 063444 ..........................Support 121943 ..............121943 Exigées) Rondelle...
  • Page 17 MARCHE CHAUFFE-EAU déclenché. réenclenchement bouton l’arrèt. à mettre vide chauffe-eau fourniture l’arrèt. à L’interrupteur réparateur. téléphoner avant vérifiés être doivent suivants articles pas, s’allumera gaz. conduites purgé soit l’air tout avant d’allumage D’EMMAGASINAGE.) L’ASSÈCHEMENT INSTRUCTIONS cycles plusieurs exiger peut chauffe-eau marche mettre premier...
  • Page 18 à fils tous débrancher limite avec équipés sont au-dessus inscrits chauffe-eau modèles SW16DE SW16D SW12DE, SW12D, SW10DE, SW10D, modèles Figure (Voir chauffe-eau. dérivation boîte à SW16DEM SW16DE V.C.C. courant l’alimentation débrancher DSI, Modèles tous SW12DEM SW12DE SW10DEM SW10DE MODÈLES...
  • Page 19 SW16DE SW16D chauffage élément qu’un non-Suburban, d’accessoire partie SW12DEM SW12DE SW12D, aucune avec l’anode tige remplacer AVERTISSEMENT! SW10DEM SW10DM SW10DE, SW10D, MODÈLES MANUELLE ZERO À REMISE THERMOSTAT L’Hiver. Pour Préparation section à également vous Référez concessionnaire. contacter assistance, toute Pour plein.
  • Page 20 douche. bain prendre avant main contact bref l’eau température èvaluer toujours doit brulûre. risques exposées plus sont handicapées âgées personnes enfants chaude. l’eau l’utilisation lors ľappareil. subis nature cette dommages prudent très être donc doit mort. d’entrainer susceptibles graves, couvre limitée garantie commange:...
  • Page 21 électriques branchements SW16DEM. SW12DEM SW10DEM, SW10DM, modèle C.C. dérivation boîte l'emplacement pour Figures référer SW16DE. SW16D SW12DE, SW12D SW10DE, SW10D, modèles C.C. dérivation boîte l'emplacement pour Figure à référer d’arrèt. position à soit chauffant l’élément commutateur à veiller connexion, boîte...
  • Page 22 DOIT INSTALLÉ QUAND CHAMBRANLE MONTRÉE. COMME CONVENABLE V.D.C. L'ATTACHE METTRE L'OUVERTURE DÉRIVATION BOÎTE AUTOUR CALFATER ENCADREE L'OUVERTURE SW16D, SW12D, CALFATAGE SW10D, FIGURE (VOIR FROIDE MOTEUR À L'AIDE CHAMBRANLE MODÈLES ENCADRÉE L'OUVERTURE C.C. DÉRIVATION BOÎTE D'ACCÈS MODULE TABLEAU FEMELLE TUYAU DEMI-RACCORD Figure ENVIRON.
  • Page 23 1192: NFPA monté être doit chauffe-eau. fixée n'est SW16DE SW16D Récréation Véhicules pour américaine Nationale Norme récente SW12DE, SW12D, SW10DE, SW10D, modèles module carte plus l’édition Z223.1/NFPA ANSI National Combustible Code porte. attacher pour degrés verrou Tourner porte. dans fente récente...
  • Page 24 D’ALLUMER ESSAYER • SENTEZ VOUS FAIRE SÉCURITÉ VOTRE POUR MOBILE LOGEMENT RÉCRÉATION VÉHICULES DANS L’INSTALLATION POUR SW16DEM • SW16DE • SW16D SW12DEM • SW12DE • SW12D SW10DEM • SW10DM • SW10DE • SW10D MODÈLES CHAUFFE-EAU DIRECTE VENTOUSE D’EXPLOITATION D’INSTALLATION MANUEL...

Table of Contents