06/11/06 12:22:11 32Z6J600_007

SAFETY PRECAUTIONS

Make sure the engine is off before you begin any maintenance
or repairs. This will eliminate several potential hazards:
Carbon monoxide poisoning from engine exhaust.
Be sure there is adequate ventilation whenever you operate
the engine.
Burns from hot parts.
Let the engine and exhaust system cool before touching.
Injury from moving parts.
Do not run the engine unless instructed to do so.
Read the instructions before you begin, and make sure you have
the tools and skills required.
To reduce the possibility of fire or explosion, be careful when
working around gasoline. Use only a non-flammable solvent,
not gasoline, to clean parts. Keep cigarettes, sparks and flames
away from all fuel related parts.
Remember that an authorized Honda servicing dealer knows your
engine best and is fully equipped to maintain and repair it.
To ensure the best quality and reliability, use only new genuine
Honda parts or their equivalents for repair and replacement.
MAINTENANCE SCHEDULE
REGULAR SERVICE PERIOD (3)
Perform at every
Each
indicated month or
use
operating hour interval,
whichever comes first.
ITEM
Engine oil
Check level
Change
Air cleaner
Check
Clean
Spark plug
Check-adjust
Replace
Timing belt
Check
Spark arrester
Clean
(Applicable
types)
Exhaust Filter
Clean
(Applicable
types)
Engine cooling
Check
fins
Nuts, bolts,
Check
fasteners
(Retighten if necessary)
Clutch shoes
Check
Idle speed
Check-adjust
Valve
Check-adjust
clearance
Combustion
Clean
chamber
Fuel filter
Check
Fuel tank
Clean
Fuel tubes
Check
Every 2 years (Replace if necessary) (2)
Oil tube
Check
Every 2 years (Replace if necessary) (2)
(1)
Service more frequently when used in dusty areas.
(2)
These items should be serviced by your Honda servicing
dealer, unless you have the proper tools and are mechanically
proficient. Refer to the Honda shop manual for service
procedures.
(3)
For commercial use, log hours of operation to determine
proper maintenance intervals.
(4)
Check that there is no crack and abnormal wear-out in the belt,
and replace if it is abnormal.
Failure to follow this maintenance schedule could result in non-
warrantable failures.
ENGLISH
First
Every 3
Every 6
Every
Every 2
month
months
months
year
years
or
or
or
or
or
10 hrs
25 hrs
50 hrs
100 hrs
300 hrs
(1)
After every 300 hrs (2) (4)
manual
12 14
(2)
manual
(2)
manual
(2)
manual
After every 300 hrs. (2)
manual
manual
manual
Refer
to
Page
9
10
11
Shop
13
11
4
Shop
Shop
Shop
Shop
12
12
Shop
Shop
7