SEDIMENT CUP CLEANING
1.
Move the fuel valve
to
the
OFF
position, then remove the fuel
sediment cup and O-ring.
Gasoline is highly flammable and explosive, and you can
be burned or seriously injured when handling fuel.
Stop engine and keep heat, sparks, and flame away.
Handle fuel only outdoors.
Wipe up spills immediately.
2.
Wash the sediment cup and O-ring in nonflammable solvent,
3. Place the O-ring in the fuel valve, and install the sediment cup.
4. Move the fuel valve to the ON position, and check for leaks.
and dry them thoroughly.
Tighten the sediment cup securely.
Replace the O-ring it there is any leakage.
FUEL VALVE
O-RING
SEDIMENT CUP
SPARK ARRESTER (optional equipment)
In some areas, it is illegal to operate an engine without a USDA (United
States Department of Agriculture)-qualified spark arrester. Check local
laws and regulations. A USDA-qualified spark arrester is available from an
authorized Honda servicing dealer.