SERVICING YOUR ENGINE

SEDIMENT CUP CLEANING

1.
Move the fuel valve to the OFF position, then remove the fuel
sediment cup and O-ring.
2.
Wash the sediment cup and O-ring in nonflammable solvent, and
dry them thoroughly.
3.
Place the O-ring in the fuel valve, and install the sediment cup.
Tighten the sediment cup securely.
4.
Move the fuel valve to the ON position, and check for leaks.
Replace the O-ring if there is any leakage.
36
Gasoline is highly flammable and
explosive.
You can be burned or seriously
injured when handling fuel.
Keep heat, sparks and flame away.
Handle fuel only outdoors.
Wipe up spills immediately.
O-RING