Inner Filter (paper) Type:
Tap the inner filter (1) lightly several times on a hard surface to remove
excess dirt, or blow compressed air lightly (207 kPa (2.11 kgf/cm
less) through the paper filter from the inside out. Never try to brush the dirt
off; brushing will force dirt into the fibers.
Wipe dirt from the inside of the air cleaner case and the air cleaner cover,
using a rag.
Check the air cleaner case packing for deterioration or damage. Make sure
the air cleaner packing is installed securely.
Install the cleaner in the reverse order of removal.

Sediment Cup Cleaning

WARNING
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when
handling fuel.
• Keep heat, sparks, and flame away.
• Handle fuel only outdoors.
• Wipe up spills immediately.
Turn the fuel valve lever (1) to the OFF position.
Remove the sediment cup (2) and the O-ring (3).
Release the tabs (5) and remove the cup filter (4).
Clean the sediment cup and the cup filter with non-flammable solvent and
allow them to dry thoroughly.
Install the cup filter as the direction shown in the illustration.
Install a new O-ring and tighten the sediment cup to the specified torque.
TORQUE: 3.9 N·m (0.40 kgf·m, 2.9 lbf·ft)
Check the sediment cup for any sign of fuel leakage.
44
GX240 • GX270 • GX340 • GX390 (UT2/RT2) Technical Manual
2
, 30 psi) or
(1)
(3)
(2)
CARBURETOR
BOSS
© 2010 American Honda Motor Co., Inc — All Rights Reserved
(1)
OFF
BOSS
(5)
(5)
UNDER VIEW:
ON
(5)
(4)
(5)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx390Gx270Gx340

Table of Contents