Maintenance - Dyna-Glo RA18LPDG User Manual

Dyna-glo pro & delux propane construction heater
Hide thumbs Also See for RA18LPDG:
Table of Contents

Advertisement

PROPANE CONSTRUCTION HEATER
Repair should be done by a qualified service person. The appliance should be inspected before use and at
least annually by a professional service person. More frequent cleaning may be required due to excessive
debris. it is imperative that control compartments, burners and circulating air passageways of the heater be
kept clean. dust, lint, cobwebs or debris may affect heater performance. The heater draws air into it during
normal operation and in the process dust, lint or debris may be drawn into it. Before cleaning ensure the gas
supply is turned off at the cylinder and the gas control knob is in the "oFF" position.
Each time you light the heater check that the pilot flame and burner flame patterns are as shown in fugures 4
and 5. If flame patterns are incorrect, turn the heater off and contact your dealer or qualified service person for
assistance. Do not operate the heater until the pilot and burner flames are correct.
Note: Do not mistake orange flames with yellow tipping. Dirt or dust particles may enter the burner flames and
cause transient patches of orange flame.
FiguRe 4 proper pilot Flame
Thermocouple
ignitor electrode
Correct
Clean the exterior with soft bristle brush, vacuum cleaner or pressurized air. Never use a wooden toothpick as
it may break off and clog the odS pilot or main burner port.
Use a flashlight to inspect the main burner inlet to ensure it is not blocked. If obstruction can be seen, use a
metal coat hanger that has been straightened out. use a vacuum cleaner to clean the primary air openings
to the main burners.
waRning: FailuRe To Keep The pRiMaRy aiR openingS To The BuRneR(S) Clean
"May ReSulT in SooTing, pRopeRTy daMage and inCReaSed CaRBon Monoxide
pRoduCTion".
In order to clean ODS pilot orifice, use pressurized air to blow dust out through the primary air opening on the
side of the pilot.
Use a vacuum cleaner or pressurized air to clean the combustion and circulating air passageways and a damp
cloth to clean the cabinet/casing.

MAINTENANCE

Pilot and Burning Inspection
incorrect
Burner and ODS Pilot Cleaning
Cleaning Air Passageways and Unit Casings
FIGURE 5
Correct Burner Flame pattern
Correct
incorrect
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ra18lpdgdRa18lpdgpRa18lpbRa18lpaRa18lpc

Table of Contents