Operator Maintenance Instructions - Dyna-Glo PROFESSIONAL OHIR18LV Operating Instructions And Owner's Manual

Gas fired infra-red workshop heater
Hide thumbs Also See for PROFESSIONAL OHIR18LV:
Table of Contents

Advertisement

Available languages

Available languages

GAS FIRED INFRA-RED WORKSHOP HEATER

OPERATOR MAINTENANCE INSTRUCTIONS

1. TROUBLESHOOTING
A. Table 4 lists the common malfunctions which you
may find during the operation or maintenance of
your heater.
B. In the event results cannot be obtained after
performing all listed solutions, call the factory.
2. ADJUSTING THE PILOT FLAME
The pilot flame should envelop 3/8 to 1/2 in. (10 to
13 mm) of the tip of the generator. Refer to Figure
11. To adjust:
STANDARD PRESSURE
REGULATOR
12
PILOT FLOW ADJUSTING SCREW
(BENEATH COVER SCREW)
PRESSURE REGULATOR
ADJUSTMENT
Figure 12. Top View of Standard Capacity Gas Control
PROPER FLAME
ADJUSTMENT
Figure 11. Proper Flame Adjustment
A. Remove pilot adjustment cover screw. Refer to
Figure 12.
B. Turn inner adjustment screw clockwise
decrease or counterclockwise
pilot flame.
C. Always replace cover screw after adjustment and
tighten firmly to ensure proper operation.
PILOTSTAT
POWER UNIT
3/8 TO 1/2 INCH
(10-13 MILLIMETERS)
THERMOPILE
to increase
PILOT GAS OUTLET
GAS INLET
WRENCH BOSS
MANUAL GAS
CONTROL KNOB
to