Access Codes

When Access Codes is selected from the Options menu, the keypad prompts for a Master Code. When a
valid Master Code is entered, a numeric keypad is displayed with arrows to scroll to the desired user to
add/edit. Press the select button to enter the user options.
Set Access Code – adds/edits the 4-digit code.
Set Partitions – assigns the user to partitions.
User Options – enables/disables different options for the user.
Delete User – deletes the user from the system.
The access codes have programmable attributes which allow zone bypassing, remote access using the
ESCORT5580TC or one-time use activation.
Master Code (Access Code 40) - The master code, if programmed, can only be changed by the
installer.
Supervisor Codes - These codes can be used to program additional codes which have equal or lesser
attributes. Once programmed, the supervisor codes receive the master code's attributes. These attributes
are changeable. Any user code can be made a supervisor code by enabling User Code Attribute 1
(please see below for details).
Duress Codes - Duress codes are standard user codes that transmit the Duress Reporting Code when
entered to perform any function on the system. Any user code can be made a duress code by enabling
User Code Attribute 2 (please see below for details).
NOTE: Duress codes are not valid when entering User Programming, Master Functions or
Installer's sections.
NOTE: Access codes cannot be programmed as a duplicate or as a "Code +/- 1".

User Code Attributes

1. The default attributes of a new code will be the attributes of the code used to enter User Pro-
gramming whether it is a new code or an existing code being programmed.
2. System Master Code 40 has partition access for all partitions, as well as attributes 3-4 ON by
default.
NOTE: These attributes are not changeable.

Inherent Attributes (all codes except installer and maintenance)

Arm/Disarm - Any access code with partition access enabled will be valid for arming and disarming
that partition.
Command Outputs ([*][7][1], [*][7][2], [*][7][3], and [*][7][4]) - If these outputs require access
code entry, any Access Code with partition access will be valid for performing the command output
functions on that partition.

Programmable Attributes

1. Supervisor Code
2. Duress Code
3. Zone Bypassing Enabled
4. ESCORT Access

Bell Squawk Attribute

This attribute is used to determine whether an access code should generate an arming/disarming Bell
Squawk upon entry of the code for Away arming. The wireless keys with access codes associated with
them may generate Arming/Disarming Bell squawks. If desired, this option may be used with codes that
are manually entered. Please contact your installer to have this programmed.
NOTE: The Master Code cannot use the Bell Squawk attribute, but is required to enable it for
other codes.
NOTE: This feature cannot prevent the Arming/Disarming squawks from being generated if an
access code assigned to a wireless key is manually entered at a keypad.

Partition Assignment Mask

The master code has access to all partitions, and cannot be modified.
5. For Future Use
6. For Future Use
7. Bell Squawk upon Arming/
Disarming