User Options

Access Codes

More > User Options > Access Code Programming
When Access Code Programming is selected from the User Options menu, the keypad prompts for a
Master Code. When a valid Master Code is entered, a numeric keypad is displayed with arrows to scroll
to the desired user to add/edit. Press the select button to enter the user options.
– adds/edits the 4-digit code.
Set Access Code
Prox Tag Programming
– enables/disables different options for the user.
User Options
– deletes the user from the system.
Delete User
The access codes have programmable attributes which allow zone bypassing, remote access using the
ESCORT5580TC or one-time use activation.
Master Code (Access Code 40)
NOTE: The master code's attributes cannot be changed.
- These codes can be used to program additional codes which have equal or lesser
Supervisor Codes
attributes. Once programmed, the supervisor codes receive the master code's attributes. These attributes
are changeable. Any user code can be made a supervisor code by enabling User Code Attribute 1
(please see below for details).
- Duress codes are standard user codes that transmit the Duress Reporting Code to the cen-
Duress Codes
tral station when they are entered to perform any function on the system. Any user code can be made a
duress code by enabling User Code Attribute 2 (please see below for details).
NOTE: Duress codes are not valid when entering User Options, Master Functions or Installer's
sections.
NOTE: Access codes cannot be programmed as a duplicate or as a "Code +/- 1". The keypad will
notify you if a duplicate code is entered. If a duplicate code is found, an error tone is given and the
code is returned to what it was before it was changed. This applies to both 4 and 6-digit codes.

User Code Attributes

1. The default attributes of a new code will be the attributes of the code used to enter User Pro-
gramming whether it is a new code or an existing code being programmed.
2. System Master Code 40 has attributes 3-4 ON by default.
NOTE: These attributes are not changeable.
Inherent Attributes (all codes except installer and maintenance)
- Any access code will be valid for arming and disarming that partition.
Arm/Disarm
- If these outputs require access code entry, any Access Code will be valid for per-
Command Outputs
forming command output functions.
Figure 9 - User Options
– enrolls proximity tags. (Only available on WTK5504P.)
- The master code, if programmed, can only be changed by the installer.