Table 4.116 Send Diagnostic Command: Parameter List Configuration; Table 4.117 Page Code - Fujitsu MAX3036RC SERIES Specifications

Serial attached scsi interface specifications
Hide thumbs Also See for MAX3036RC SERIES:
Table of Contents

Advertisement

Command Specifications

Table 4.116 SEND DIAGNOSTIC command: parameter list configuration

Byte
0
1
Header
2
3
4
Page
~
~
Parameter
n
Page code
This field specifies the code which identifies the type of parameter page
being transferred from the INIT and the operation that should be executed.
The parameter pages which can be specified by the INIT and their functions
are as shown Table 4.117.
Page Code (Hex)
Page parameter length
This field specifies the byte length of the page parameter after byte 4. The
INIT must specify the same value as the length specified for each of the
parameter pages, which will be explained later.
Page parameter
This field specifies each of the inherent parameters in each page code.
Depending on the page code, this field may not be necessary (page parameter
length = 0).
4-178
Bit
7
6
0
0
Page Parameter Length (MSB)
Page Parameter Length (LSB)
~
~

Table 4.117 Page code

00
Reports a list of the supported page codes.
40
Logical/Physical Address Conversion
5
4
3
2
Page Code
0
0
0
0
Parameter
Function
1
0
0
0
~
~
C141-C012

Advertisement

Table of Contents
loading