Replacement routines
4.4

Replacing the SAS/SATA backplane

The drive cage has its own small SAS/SATA backplane. This backplane is
spared as an item in its own right. The expansion box, however, is spared as a
whole. You therefore do not change the backplane in the expansion box, but
change the whole expansion box completely.
Changing the drive cage:
Ê Open the server as described in the
Ê Remove the drive cage as described in the
page 17
ff.
Ê Remove the hot-plug hard disk modules at the left or right side (for a
description see the Operating Manual).
V
CAUTION!
Make sure that all hard disk modules are uniquely identified so that you
can reinsert them into their original bays.
Figure 12: Unlocking the backplane holder
Ê Unlock the backplane holder by popping up the green clamp
page
27).
Ê Pull off the backplane upwards from the drive cage.
Ê Insert the new backplane from upwards into the holder.
TX120 S2
Replacing the SAS/SATA backplane
section "Preparation" on page 17
Service Supplement
section "Preparation" on
(figure 12 on
ff.
27