Code(hex)
0000
Command complete without error.
0001
Invalid Function Code.
0002
Input LBA out of range.
0003
Request sector count over flow.
0004
Invalid Function Code in Error Recovery Control command.
0005
Invalid Selection Code in Error Recovery Control command.
0006
Host read command timer is less than minimum value.
0007
Host write command timer is less than minimum value.
Background SCT command was aborted because of an interrupting
0008
host command.
Background SCT command was terminated because of
0009
unrecoverable error.
000A
Invalid function code in LONG SECTOR ACCESS command.
SCT data transfer command was issued without first issuing an SCT
000B
command.
000C
Invalid function code in Feature Control command.
000D
Invalid Feature Code in Feature Control command.
000E
Invalid New State in Feature Control command.
000F
Invalid Option Flag in Feature Control command.
0010
Invalid Action Code.
0011
Invalid Table ID.
0012
Command was aborted due to drive security being locked.
0013
Invalid revision code.
Foreground SCT operation was terminated because of
0014
unrecoverable error.
0015 to BFFF Reserved
C000 to FFFE Vender specific.
C141-E259

Table 5.25 SCT STATUS code

Definition