Interface
•
Error reporting conditions
(1) The command has been issued more than twice (ST = 51h, ER = 10h).
(2) The READ NATIVE MAX ADDRESS command has not been issued prior to
the SET MAX ADDRESS command (ST = 51h, ER = 04h).
(3) The SET MAX ADDRESS (EXT) command has been issued
(ST = 51h, ER = 04h).
(4) A SATA communication error occurred (ST = 51h, ER = 14h).
At command issuance (Shadow Block Registers setting contents)
CM
DH
CH
CL
SN
SC
FR
At command completion (Shadow Block Registers contents to be read)
ST
DH
CH
CL
SN
SC
ER
•
SET MAX SET PASSWORD (Features Field = 01h)
This command requests a transfer of 1 sector of data from the host, and defines the
contents of SET MAX password. The password is retained by the device until the
next power cycle.
5-138
1
1
1
1
x
L
x
x
CYL No. [MSB] / LBA
CYL No. [LSB] / LBA
SCT No.
xx
xx
Status information
x
x
x
x
CYL No. [MSB] / LBA
CYL No. [LSB] / LBA
SCT No.
xx
Error information
1
0
0
1
HD No./LBA
/ LBA[LSB]
VV
xx
/ LBA[LSB]
C141-E259