Dell PowerEdge T100 Series Hardware Owner's Manual page 24

Hide thumbs Also See for PowerEdge T100 Series:
Table of Contents

Advertisement

Table 1-6. System Messages (continued)
Message
PCIe Training
Error: Slot n
Plug & Play
Configuration Error
Read fault
Requested sector
not found
Remote
Configuration
update attempt
failed
SATA port A/B/C/D
hard disk drive
configuration error
24
About Your System
Causes
Faulty or improperly
installed PCIe card in the
specified slot number.
Error encountered in
initializing PCI device;
faulty system board.
The operating system
cannot read from the
diskette or hard drive, the
system could not find a
particular sector on the
disk, or the requested sector
is defective.
System could not
implement Remote
Configuration request.
Faulty drive. Parameters
failure.
Corrective Actions
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 70. If the problem
persists, see "Getting Help"
on page 141.
Install the NVRAM_CLR
jumper and reboot the
system. See Figure 6-1 for
jumper location. Check for
a BIOS update. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 127. If the problem
persists, see "Getting Help"
on page 141.
Replace the diskette.
Ensure that the diskette
and hard-drive cables are
properly connected. See
"Troubleshooting a USB
Device" on page 110 or
"Troubleshooting a Hard
Drive" on page 124 for the
appropriate drive(s)
installed in your system.
Retry Remote
Configuration.
Ensure that the hard drive
cables are properly
connected. See
"Troubleshooting a Hard
Drive" on page 124.

Hide quick links:

Advertisement

Table of Contents
loading