Table 1-6. System Messages (continued)
Message
Not a boot diskette The operating system is
Option ROM Checksum
Error
PCIe Degraded Link
Width Error:
Embedded
Bus# nn /Dev# nn /Func n
Expected Link Width
is n
Actual Link Width
is n
PCIe Degraded Link
Width Error: Slot n
Expected Link Width
is n
Actual Link Width
is n
PCIe Training
Error: Embedded
Bus# nn /Dev# nn /Func n
Causes
trying to boot from a
diskette that does not have
a bootable operating system
installed on it.
PCI device BIOS (Option
ROM) checksum failure is
detected during shadowing.
Faulty or improperly
installed PCIe card.
Faulty or improperly
installed PCIe card in the
specified slot number.
Faulty or improperly
installed PCIe card.
Corrective Actions
Insert a diskette that has a
bootable operating system.
Ensure that all appropriate
cables are securely
connected to the expansion
cards. If the problem
persists, see
"Troubleshooting
Expansion Cards" on
page 127.
Reseat the PCIe cards. See
"Expansion Cards" on
page 70. If the problem
persists, see "Getting Help"
on page 141.
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 70. If the problem
persists, see "Getting Help"
on page 141.
Reseat the PCIe cards. See
"Expansion Cards" on
page 70. If the problem
persists, see "Getting Help"
on page 141.