Montigo M40DV-ST Installation & Operation Manual

Montigo M40DV-ST Installation & Operation Manual

See-thru gas fireplace
Hide thumbs Also See for M40DV-ST:

Advertisement

Questions? Email us at fireplaces@montigo.com or visit our website at www.montigo.com.
Installation
Operation &
Maintenance
See-Thru
Gas Fireplace
Check local codes and
n
read all instructions
prior to installation.
Leave this manual with
n
the owner.

Advertisement

Table of Contents
loading

Summary of Contents for Montigo M40DV-ST

  • Page 1 Questions? Email us at fireplaces@montigo.com or visit our website at www.montigo.com. Installation Operation & Maintenance See-Thru Gas Fireplace Check local codes and read all instructions prior to installation. Leave this manual with the owner.
  • Page 2 M40DV-ST See-Thru Gas Fireplace Table Of Contents Introduction Page 2 P/N XG0207...
  • Page 3: Installation

    M40DV-ST See-Thru Gas Fireplace Installation Installing The Fireplace Shell Top* 8" Ends 1½" Floor Combustible Mantle** 6" Flue Cover 1 1/2" P/N XG0207 Page 3...
  • Page 4: Installing The Gas Line

    M40DV-ST See-Thru Gas Fireplace Installation Installing The Gas Line Vent Installation * After gas line is connected each appliance connection, valve and valve train must be checked while under normal operating pressure with either a liquid solution, or leak detection device, to locate any source of leak. Tighten any...
  • Page 5: Vent Terminations

    M40DV-ST See-Thru Gas Fireplace Installation Vent Terminations PTO-3F PTKOG PTO-3 MOSR 12 12 PTO-3 P/N XG0207 Page 5...
  • Page 6: Rear Vent Venting Requirements

    M40DV-ST See-Thru Gas Fireplace Installation Rear Vent Converting to Top Vent/ Side Vent Venting Requirements (Installing the Flue Cover) Center of vent 29½" Example A: (Acceptable Installation) Example B: (Acceptable Installation) Example C: (Unacceptable Installation) Page 6 P/N XG0207...
  • Page 7: Horizontal Vent Installation

    M40DV-ST See-Thru Gas Fireplace Installation Installation Installation Installation Installation Horizontal Vent Installation A - Termination PTO-3 PTO-3F B - Stucco Kits MSR (stucco frame) MOSR (stucco can) D - Flex sections PFL-1 (12" section) PFL-2 (24" section) PFL-3 (36" section) PFL-4 (48"...
  • Page 8 M40DV-ST See-Thru Gas Fireplace Installation Vertical Vent Installations Page 8 P/N XG0207...
  • Page 9: Top Vent Venting Requirements

    M40DV-ST See-Thru Gas Fireplace Installation Top Vent Venting Requirements Installation Of Top Vent DV A - Termination PTO-3 (3" length) PTO-3F (3" length) B - Stucco Kits MSR (stucco frame) MOSR (stucco can) C - Flex sections PFL-1 (12" section) PFL-2 (24"...
  • Page 10 M40DV-ST See-Thru Gas Fireplace Installation Example: Page 10 P/N XG0207...
  • Page 11 M40DV-ST See-Thru Gas Fireplace Installation Installation Installation Installation Installation Installation Of Vertical Vent DV A - Termination PVTK-1 B - Flex sections PFL-1 (12" section) PFL-2 (24" section) PFL-3 (36" section) PFL-4 (48" section) C - Solid sections PEXT-1 (12" section) PEXT-2 (24"...
  • Page 12: Finishing Around The Fireplace

    M40DV-ST See-Thru Gas Fireplace Installation Reduced Vertical Installation A - Termination PVTK-1 MVTK-1 B - Flex sections 12" length PFL-1 MFL-1 24" length PFL-2 MFL-2 36" length PFL-3 MFL-3 48" length PFL-4 MFL-4 C - Solid sections 12" length PEXT-1 MEXT-1 24"...
  • Page 13 M40DV-ST See-Thru Gas Fireplace Installation Wiring Honeywell (Q3450) Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control (SV9501M) Gas Control Junction Box Cover Connector Fuse Junction Box Fan Plug Receptacle Black 115VAC White Green 24VAC Grnd Screw 40 VA Transformer...
  • Page 14: Installing The Logs And Embers

    M40DV-ST See-Thru Gas Fireplace Operation Installation Installing the Logs and Embers Lighting Instructions Burner Adjustment WARNING: WARNING: WARNING: WARNING: WARNING: If logs are not placed properly, excessive sooting will result. L o g 'D ' L o g 'C '...
  • Page 15: To Turn Off Gas To Appliance

    M40DV-ST See-Thru Gas Fireplace Operation - Model M40DV-ST with Continuous Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 16 M40DV-ST See-Thru Gas Fireplace Operation - Model M40DV-ST-I with Honeywell Intermittent Pilot For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 17: Maintenance

    M40DV-ST See-Thru Gas Fireplace Maintenance Gas Control Valve Power Generator Pilot Adjustment Screw Wall Switch General Inlet Pressure Manifold Pressure Test Connection Pilot Burner Adjustment Cleaning P/N XG0207 Page 17...
  • Page 18: Troubleshooting

    M40DV-ST See-Thru Gas Fireplace Maintenance Troubleshooting Troubleshooting Before Troubleshooting, Familiarize Yourself With The Startup And Checkout Procedure. Page 18 P/N XG0207...
  • Page 19: Warranty

    Other Rights Other Rights Other Rights Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. P/N XG0207...
  • Page 20: Appendix A - Termination Locations

    M40DV-ST See-Thru Gas Fireplace Appendix A - Termination Locations Page 20 P/N XG0207...
  • Page 21: Appendix B - M40Dv-St-Mh Mobile Home

    M40DV-ST See-Thru Gas Fireplace Appendix B - M40DV-ST-MH Mobile Home Power Generator Pilot Adjustment Screw Wall Switch Inlet Pressure Manifold Pressure Test Connection P/N XG0207 Page 21...
  • Page 22 XG0207 Rev.01 - 10/2001 Canadian Heating Products Inc. Montigo Del Ray Corp.